SPD, HEPD type 1, 120/240 V, 1 PH, 3 wire, 80 kA| Accessory Category: Mounting accessory Surge Current: 80 kA per phase Voltage Rating: 120/240 V AC Number of Phases: 1 phase Wiring Configuration: 3-wire (isolated ground) Connection: Wire AWG 14 MCOV: 150 V Nominal Discharge Current: 10 kA Rated Current: 10 kA SCCR: 25 kA Local Signaling: 1 LED green normal operation, 1 LED green off Mounting Location: Side Mounting Support: Bracket product destination: Load center input voltage: 600 V L-N, 600 V L – G, 1000 V L – L, 900 V N - G Height: 3.23 in (82.04 mm) Width: 3.72 in (94.49 mm) Depth: 2.10 in (53.34 mm) Cable length: 34 in (863.60 mm) Enclosure Rating: NEMA 4X
- [Uc] maximum continuous operating voltage : 150 V~~
- [Ue] rated operational voltage : 120/240 V AC
- Brand : Square D
- By Schneider : Yes
- Cable Length : 34 in (863.6 mm)
- Connections - Terminals : Wire AWG 14
- Depth : 2.10 in (53.34 mm)
- Device Short Name : HEPD
- Enclosure Material : Non-metallic
- Final Result for Connectable : Not connectable
- Final Result for Flywheel performance tracking : Non Flywheel
- Global Keywords : protection
- Global Keywords : 80kA
- Global Keywords : HEPD
- Global Keywords : SPD type 1
- Global Keywords : Surge
- Height : 3.23 in (82.04 mm)
- Indivisible Sale Qty : 1
- Input Voltage : 1000 V L - L
- Input Voltage : 600 V L - G
- Input Voltage : 600 V L-N
- Input Voltage : 900 V N - G
- Line Rated Current : 10 kA
- Local Signalling : 1 LED green normal operation
- Local Signalling : 1 LED green off
- Manufacturer : Schneider Electric
- NEMA Protection Rating : NEMA 4X
- Nominal Discharge Current : 10 kA
- Number of Units in Package 2 : 3
- Package 2 GTIN : 30785901008720
- Package 2 Height : 6.80 in (17.272 cm)
- Package 2 Length : 11.20 in (28.448 cm)
- Package 2 Weight : 3.620 lb(US) (1.642 kg)
- Package 2 width : 8.70 in (22.098 cm)
- Packaging made with recycled cardboard : No
- Packaging without single use plastic : No
- Phase : 1 phase
- Product Destination : Load center
- Product Or Component Type : Surge protection device
- short-circuit protection : 25 kA
- Standards : CUL
- Standards : UL 1449
- Standards : UL 1449:ed. 4: type I
- surge arrester type : Electrical distribution network
- surge current : 80 kA per phase
- Take-back : No
- Temperature Ambient Operating Range : -40…149 °F (-40…65 °C)
- Unit Type of Package 2 : CAR
- UNSPSC Classification v19 : 39121101
- UNSPSC Classification v23 : 39121101
- Volume of Package 2 : 10857.938 cm3
- Width : 3.72 in (94.49 mm)
- wiring configuration : 3-wire (isolated ground)