TeSys D Contactor |Number of Poles: 3-Poles|Pole Contact Composition: 3 NO|Rated Operational Current: 65A|Control Circuit Voltage: 110V AC 50/60 Hz|Non-Reversing
- [Ie] rated operational current : 65 A (at~~
- [Ie] rated operational current : 65 A (at
- [Ie] rated operational current : 80 A (at
- [Ith] conventional free air thermal current : 10 A (at 140 °F (60 °C)) for control circuit
- [Ith] conventional free air thermal current : 80 A (at 140 °F (60 °C)) for power circuit
- [Uc] control circuit voltage : 110 V DC
- [Ue] rated operational voltage : Power circuit
- [Ui] rated insulation voltage : Control circuit 600 V CSA
- [Ui] rated insulation voltage : Control circuit 600 V UL
- [Ui] rated insulation voltage : Control circuit 690 V IEC 60947-1
- [Ui] rated insulation voltage : Power circuit 600 V CSA
- [Ui] rated insulation voltage : Power circuit 600 V UL IEC 60947-1
- [Ui] rated insulation voltage : Power circuit 690 V CSA IEC 60947-1
- [Uimp] rated impulse withstand voltage : 8 kV IEC 60947
- Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1
- Associated Fuse Rating : 125 A gG at
- Associated Fuse Rating : 160 A gG at
- auxiliary contact composition : 1 NO + 1 NC
- auxiliary contacts type : Mechanically linked 1 NO + 1 NC IEC 60947-5-1
- auxiliary contacts type : Mirror contact 1 NC IEC 60947-4-1
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 83
- Circularity Profile : No need of specific recycling operations
- climatic withstand : IACS E10 exposure to damp heat
- coil technology : Built-in bidirectional peak limiting diode suppressor
- Connections - Terminals : Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid
- Connections - Terminals : Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid
- Connections - Terminals : Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: rigid
- contactor application : Motor control
- contactor application : Resistive load
- control circuit type : DC standard
- control circuit voltage limits : 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC
- control circuit voltage limits : 0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
- control circuit voltage limits : 0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz
- control circuit voltage limits : 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz
- control circuit voltage limits : 1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz
- Depth : 6.9 in (176 mm)
- Device Short Name : LC1D
- Final Result for Flywheel performance tracking : Non Flywheel
- fire resistance : 1562 °F (850 °C) IEC 60695-2-1
- Flame Retardance : V1 conforming to UL 94
- Global Keywords : AC coil
- Global Keywords : AC control
- Global Keywords : CTR
- Global warming ; Total life cycle? : 83 kg CO2 eq.
- Height : 5 in (127 mm)
- Hold-In Power Consumption In Va : 15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
- Hold-In Power Consumption In W : 7.4 W 68 °F (20 °C)
- inrush power in VA : 160 VA cos phi 0.75 (at 68 °F (20 °C))
- Inrush Power In W : 19 W 68 °F (20 °C))
- insulation resistance : > 10 MOhm for control circuit
- IP Degree of Protection : IP2x IEC 60529
- IP Degree of Protection : IP2x VDE 0106
- Irms rated making capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
- Irms rated making capacity : 140 A AC for control circuit conforming to IEC 60947-5-1
- Irms rated making capacity : 250 A DC for control circuit conforming to IEC 60947-5-1
- Manufacturer : Schneider Electric
- Maximum Horse Power Rating : 10 hp at 230/240 V AC 60 Hz for 1 phase motors
- Maximum Horse Power Rating : 20 hp at 200/208 V AC 60 Hz for 3 phase motors
- Maximum Horse Power Rating : 20 hp at 230/240 V AC 60 Hz for 3 phase motors
- Maximum Horse Power Rating : 40 hp at 460/480 V AC 60 Hz for 3 phase motors
- Maximum Horse Power Rating : 5 hp at 115 V AC 60 Hz for 1 phase motors
- Maximum Horse Power Rating : 50 hp at 575/600 V AC 60 Hz for 3 phase motors
- maximum operating rate : 3600 cyc/h at 60 °C
- Mechanical Durability : 10000000 cycles
- Mechanical Robustness : Shocks contactor closed 15 Gn for 11 ms)
- Mechanical Robustness : Shocks contactor opened 10 Gn for 11 ms)
- Mechanical Robustness : Vibrations contactor closed 4 Gn, 5...300 Hz)
- Mechanical Robustness : Vibrations contactor opened 2 Gn, 5...300 Hz)
- minimum switching current : 5 mA for control circuit
- minimum switching voltage : 17 V for control circuit
- motor power kW : 11 kW at 400 V AC 50 Hz (AC-4)
- motor power kW : 18.5 kW at 220...230 V AC 50 Hz (AC-3)
- motor power kW : 18.5 kW at 220...230 V AC 50 Hz (AC-3e)
- motor power kW : 30 kW at 380...400 V AC 50 Hz
- motor power kW : 30 kW at 380...400 V AC 50 Hz (AC-3)
- motor power kW : 30 kW at 380...400 V AC 50 Hz (AC-3e)
- motor power kW : 30 kW at 415 V AC 50 Hz (AC-3)
- motor power kW : 30 kW at 415 V AC 50 Hz (AC-3e)
- motor power kW : 30 kW at 440 V AC 50 Hz
- motor power kW : 30 kW at 440 V AC 50 Hz (AC-3e)
- motor power kW : 37 kW at 1000 V AC 50 Hz (AC-3)
- motor power kW : 37 kW at 1000 V AC 50 Hz (AC-3e)
- motor power kW : 37 kW at 500 V AC 50 Hz (AC-3)
- motor power kW : 37 kW at 500 V AC 50 Hz (AC-3e)
- motor power kW : 37 kW at 660...690 V AC 50 Hz (AC-3)
- motor power kW : 37 kW at 660...690 V AC 50 Hz (AC-3e)
- Mounting Support : Plate
- Mounting Support : Rail
- Net Weight : 4.817 lb(US) (2.185 kg)
- non-overlap time : 1.5 ms on de-energisation between NC and NO contacts
- non-overlap time : 1.5 ms on energisation between NC and NO contacts
- Number of Units in Package 2 : 5
- Operating Altitude : 0...9842.52 ft (0...3000 m)
- Operating Time : 12...26 ms closing
- Operating Time : 20 ms opening
- Operating Time : 50 ms closing
- Overvoltage Category : III
- Package 2 GTIN : 43389110436875
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 16.592 lb(US) (7.526 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : No
- pole contact composition : 3 NO
- power dissipation per pole : 4.2 W AC-3
- power dissipation per pole : 4.2 W AC-3e
- power dissipation per pole : 6.4 W AC-1
- Product Certifications : BV
- Product Certifications : CCC
- Product Certifications : CSA
- Product Certifications : DNV
- Product Certifications : GL
- Product Certifications : GOST
- Product Certifications : LROS (Lloyds register of shipping)
- Product Certifications : RINA
- Product Certifications : UKCA
- Product Certifications : UL
- Product Or Component Type : Contactor
- protective cover : With
- PVC free : Yes
- Range : TeSys
- rated breaking capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
- REACh free of SVHC : Yes
- safety reliability level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- safety reliability level : B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Standards : CSA C22.2 No 14
- Standards : EN 60947-4-1
- Standards : EN 60947-5-1
- Standards : IEC 60947-5-1
- Standards : UL 508
- Take-back : No
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
- Tightening Torque : Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm
- Time Constant : 34 ms
- Toxic heavy metal free : Yes
- Type Of Network : 3P
- Unit Type of Package 2 : S02
- UNSPSC Classification v19 : 39121529
- UNSPSC Classification v23 : 39121529
- utilisation category : AC-1
- utilisation category : AC-2
- utilisation category : AC-3e
- utilisation category : AC-4
- Volume of Package 2 : 18000.000 cm3
- Warranty : 18 months
- Width : 3.3 in (85 mm)