Overview
The Honeywell SmartVFD HVAC and BYPASS are designed for commercial buildings to deliver the energy savings that building owners and managers need. Efficient install, and commissioning, in a full featured VFD.
Features
Start-up Wizards—All you have to do is tell the VFD whether you have a pump or a fan, enter nominal motor information, and you are up and running.Graphic Interface—The easy-to-use keypad and interface deliver menu-driven programming and monitoring for fast, uniform commissioning. It's also easy for the building owner or manager to learn and use, helping to reduce service calls. Plus, a manual is built into the keypad for easy access when needed.Built-in Communications—With BACnet®, N2 and Modbus built in, your customers will enjoy a lower total installed cost and reliable communications with the building management system.PC Software Wizards—Commissioning, programming and troubleshooting are all a snap thanks to these guided Startup and PID wizards.Built-in PLC—Another reason why SmartVFD HVAC is a great value for your customer, the built-in PLC eliminates the need for an expensive external controller.DC Choke for harmonic protection.Standard RIF Filter—Ensures that EMC/RFI requirements are met.Bypass Options—Meets specifications and system critical applications with a comprehensive bypass offering.Real-Time Clock—Battery included.Fire Mode for safe operation.Motor Switch Ride-Through--easy, fault-free maintenance.
- Dimensions (in.) : 5.7 x 16.5 x 8.4
- Dimensions (mm) : 144.78 x 419.1 x213.36
- Weight (lb) : 22
- Weight (kg) : 9.97
- Item Type : Product
- Frequency : 0 Hz to 320 Hz
- Voltage : 600 Vac
- Operating Temperature Range (F) : 14 F to 122 F
- Operating Temperature Range (C) : -10 C to 50 C
- Enclosure : NEMA 1
- Relay Outputs : Max. switching load: 250Vac/2A or 250Vdc/0,4A
- Horsepower : 3 HP
- Current Ratings : 3.9 A
- Analog Current Output : 0 (4) - 20 mA, max 500 ohm
- Bypass : Drive alone
- Auto Bypass : No
- Drive Family : SmartVFD HVAC
- Drive Input Disconnect : No
- Type of RFI Filter : EMC Filter
- Continuous Output Current : overload 1.5 x High overload current (1min/10min), overload 1.1 x Low overload current (1min/10min)
- Starting Torque : Depends on the Motor
- Acceleration time : 0.1 - 3000 sec
- Deceleration time : .1 - 3000 sec
- Analog Voltage Input : 0 - 10 Vdc , 200K ohm
- Analog Current Input : 0 (4) - 20 mA, 250 ohm differential
- Digital Output : Open collector, max. load 48V/50mA
- Reference Output Voltage : Maximum Load 10mA
- Auxiliary Voltage : ± 20%, max. load 50 mA
- Frame Type : 5