zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

HVFDSD3D0200G200A

$0.00
(No reviews yet) Write a Review
SKU:
HVFDSD3D0200G200A
Overview The Honeywell SmartVFD HVAC and BYPASS are designed for commercial buildings to deliver the energy savings that building owners and managers need. Efficient install, and commissioning, in a full featured VFD. Features Start-up Wizards—All you have to do is tell the VFD whether you have a pump or a fan, enter nominal motor information, and you are up and running.Graphic Interface—The easy-to-use keypad and interface deliver menu-driven programming and monitoring for fast, uniform commissioning. It's also easy for the building owner or manager to learn and use, helping to reduce service calls. Plus, a manual is built into the keypad for easy access when needed.Built-in Communications—With BACnet®, N2 and Modbus built in, your customers will enjoy a lower total installed cost and reliable communications with the building management system.PC Software Wizards—Commissioning, programming and troubleshooting are all a snap thanks to these guided Startup and PID wizards.Built-in PLC—Another reason why SmartVFD HVAC is a great value for your customer, the built-in PLC eliminates the need for an expensive external controller.DC Choke for harmonic protection.Standard RIF Filter—Ensures that EMC/RFI requirements are met.Bypass Options—Meets specifications and system critical applications with a comprehensive bypass offering.Real-Time Clock—Battery included.Fire Mode for safe operation.Motor Switch Ride-Through--easy, fault-free maintenance.
Dimensions (in.) :
7.7 x 21.9 x 9
Dimensions (mm) :
195.58 x 556.26 x228.6
Weight (lb) :
44.1
Weight (kg) :
20
Item Type :
Product
Frequency :
0 Hz to 320 Hz
Voltage :
600 Vac
Operating Temperature Range (F) :
14 F to 122 F
Operating Temperature Range (C) :
-10 C to 50 C
Enclosure :
NEMA 12
Horsepower :
20 HP
Current Ratings :
22 A
Analog Current Output :
6 (4) - 20 mA, max 500 ohm
Bypass :
Drive alone
Auto Bypass :
No
Drive Family :
SmartVFD HVAC
Drive Input Disconnect :
No
Type of RFI Filter :
EMC Filter
Starting Torque :
Depends on the Motor
Acceleration time :
0.1 - 3000 sec
Deceleration time :
.1 - 3000 sec
Analog Voltage Input :
6 - 10 Vdc , 200K ohm
Analog Current Input :
6 (4) - 20 mA, 250 ohm differential
Reference Output Voltage :
Maximum Load 10mA
Auxiliary Voltage :
± 20%, max. load 50 mA
Frame Type :
6

No Reviews Yet