IEM3465 Energy Meter - BACnet - 1 DI - 1 DO - Multi-Tariff - LVCT
- 9 mm pitches : 10~~
- Accuracy Class : Class 0.5S active energy ANSI C12.20
- Accuracy Class : Class 0.5S active energy IEC 62053-22
- Ambient Air Temperature For Operation : -13…158 °F (-25…70 °C) - IEC
- Analogue Input Type : Low voltage current transformer 0.333 V or 1 V
- Application : Multi-tariff
- Application : Partial meter
- Application : Sub billing
- Brand : Schneider Electric
- By Schneider : Yes
- California proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
- Carbon footprint (kg CO2 eq, Total Life cycle) : 70
- Color : White
- Communication Port Protocol : BACnet 9.6, 19.2, 38.4, 57.6, 76.8 kbauds
- Communication Port Support : Screw terminal block RS485
- Connections - Terminals : Communication screw terminals 0.004 in² (2.5 mm²)
- Connections - Terminals : Current circuit screw terminals 0.009 in² (6 mm²)
- Connections - Terminals : Input/output circuit screw terminals 0.002 in² (1.5 mm²)
- Connections - Terminals : Voltage circuit screw terminals 0.004 in² (2.5 mm²)
- Depth : 2.7 in (69 mm)
- Device Short Name : IEM3465
- Display Type : LCD display
- Final Result for Connectable : Connectable ready
- Final Result for Flywheel performance tracking : Connectable products
- Global Keywords : BACnet
- Global Keywords : Class 1 active energy accuracy
- Global Keywords : DIN mount energy meter
- Global Keywords : LCD display
- Global Keywords : Low voltage current transducer
- Global Keywords : LVCT
- Global Keywords : MID
- Global Keywords : Power
- Global Keywords : Pulse output
- Global Keywords : Sub-billing
- Global Keywords : Tariff switching
- Global warming ; Total life cycle? : 70 kg CO2 eq.
- Height : 3.4 in (87 mm)
- IK Degree of Protection : IK08
- Indivisible Sale Qty : 1
- Information Displayed : Tariff 4)
- IP Degree of Protection : IP20 body: conforming to IEC 60529
- IP Degree of Protection : IP40 front panel: conforming to IEC 60529
- Local Signalling : alarm overload
- Local Signalling : Green indicator light power ON
- Local Signalling : Yellow flashing LED accuracy checking
- Manufacturer : Schneider Electric
- Market Segment : Buildings large building cost management: billing: main incomer
- Market Segment : Buildings large building cost management: billing: panelboard
- Market Segment : Buildings large building cost management: billing: sub feeder
- Market Segment : Buildings medium building cost management: billing: main incomer
- Market Segment : Buildings medium building cost management: billing: panelboard
- Market Segment : Buildings medium building cost management: billing: sub feeder
- Market Segment : Buildings multi-site cost management: billing: main incomer
- Market Segment : Buildings multi-site cost management: billing: panelboard
- Market Segment : Buildings multi-site cost management: billing: sub feeder
- Market Segment : Buildings multi-site cost management: cost allocation: main incomer
- Market Segment : Buildings multi-site cost management: cost allocation: panelboard
- Market Segment : Buildings multi-site cost management: cost allocation: sub feeder
- Market Segment : Buildings small building cost management: billing: main incomer
- Market Segment : Buildings small building cost management: billing: panelboard
- Market Segment : Buildings small building cost management: billing: sub feeder
- Market Segment : Data center cost management: billing
- Market Segment : Data center cost management: cost allocation
- Market Segment : Healthcare cost management: billing
- Market Segment : Healthcare cost management: cost allocation
- Market Segment : Industry cost management: billing
- Market Segment : Industry cost management: cost allocation
- Maximum Value Measured : 99999999 MWh
- Maximum Value Measured : 99999999.9 kWh
- Measurement Current : 1…32767000 mA
- Metering Type : Active, reactive, apparent energy (signed, four quadrant)
- Mounting Mode : Clip-on
- Mounting Support : DIN rail
- Network Frequency : 50 Hz
- Network Frequency : 60 Hz
- Number Of Inputs : 1 digital 0...5 V/11...40 V 24 V DC
- Number Of Outputs : 1 digital (static)
- Number of Units in Package 2 : 30
- Number of Units in Package 3 : 240
- Output Voltage : 5...40 V DC@50 mA
- Package 2 GTIN : 43606480845237
- Package 2 Height : 11.81 in (30 cm)
- Package 2 Length : 15.75 in (40 cm)
- Package 2 Weight : 25.316 lb(US) (11.483 kg)
- Package 2 width : 11.81 in (30 cm)
- Package 3 Height : 19.69 in (50 cm)
- Package 3 Length : 23.62 in (60 cm)
- Package 3 Weight : 221.265 lb(US) (100.364 kg)
- Package 3 width : 31.50 in (80 cm)
- Packaging made with recycled cardboard : No
- Packaging without single use plastic : No
- Pollution Degree : 2
- Product Certifications : CE EN 61557-12 power monitor)
- Product Certifications : CE EN/IEC 61326-1 EMC)
- Product Certifications : CE IEC 61010-1 safety)
- Product Certifications : CULus EN 61010-1 safety)
- Product Certifications : CULus UL 61010-1 safety)
- Product Certifications : KZ
- Product Certifications : RCM
- Product Certifications : UKCA BS EN 61010-1 safety)
- Product Certifications : UKCA BS EN 61326-1 EMC)
- Product Certifications : UKCA BS EN 61557-12 power monitor)
- Product Name : Acti9 iEM3000
- Product Or Component Type : Energy meter
- Range : Acti9
- Rated Voltage : 100…277 V +/- 20 %
- Rated Voltage : 173…480 V +/- 20 %
- Relative Humidity : 5…95 % 97 °F (36 °C)
- Sampling Rate : 32 samples/cycle
- SCIP Number : B428ef47-1302-4911-8a1e-8a5fda8424b6
- Selection Tools : Power Meters
- Standards : ANSI C12.20
- Standards : BS EN 61010-1:2010
- Standards : BS EN 61010-2-30
- Standards : BS EN 61326-1
- Standards : EN 61010-1:2010
- Standards : EN 61010-2-30
- Standards : EN 61326-1
- Standards : IEC 61010-1:2010
- Standards : IEC 61010-2-30
- Standards : IEC 61326-1
- Standards : UL 61010-1:2010
- Standards : UL 61010-2-30
- Take-back : No
- Technology Type : Electronic
- Temperature Shipping and Storage Range : -40…185 °F (-40…85 °C)
- Tightening Torque : Communication: 4.4 lbf.in (0.5 N.m) Philips screwdriver
- Tightening Torque : Current circuit: 7.08 lbf.in (0.8 N.m) pozidriv screwdriver
- Tightening Torque : Input/output circuit: 4.4 lbf.in (0.5 N.m) Philips screwdriver
- Tightening Torque : Voltage circuit: 4.4 lbf.in (0.5 N.m) Philips screwdriver
- Type Of Measurement : Active and reactive energy
- Type Of Measurement : Active and reactive power
- Type Of Measurement : Current
- Type Of Measurement : Voltage
- Type Of Network : 1P + N
- Type Of Network : 3P
- Type Of Network : 3P + N
- Unit Type of Package 2 : S03
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39121117
- UNSPSC Classification v23 : 39121117
- Volume of Package 2 : 36000 cm3
- Volume of Package 3 : 240000 cm3
- Width : 3.5 in (90 mm)
- Wire Stripping Length : Communication: 0.3 in (7 mm)
- Wire Stripping Length : Current circuit: 0.3 in (8 mm)
- Wire Stripping Length : Input/output circuit: 0.2 in (6 mm)
- Wire Stripping Length : Voltage circuit: 0.3 in (8 mm)