zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

LP2K0910BD

$276.07
(No reviews yet) Write a Review
SKU:
LP2K0910BD
Adding to cart… The item has been added
TeSys K Contactor |Number of Poles: 3-Poles|Pole Contact Composition: 3 NO|Rated Operational Current: 9A|Control Circuit Voltage: 24V DC|Reversing
[Icw] rated short-time withstand current :
110 A - 100 ms for signalling circuit~~
[Icw] rated short-time withstand current :
20 A 122 °F (50 °C) - >= 15 min for power circuit
[Icw] rated short-time withstand current :
40 A 122 °F (50 °C) - 3 min for power circuit
[Icw] rated short-time withstand current :
45 A 122 °F (50 °C) - 1 min for power circuit
[Icw] rated short-time withstand current :
60 A 122 °F (50 °C) - 30 s for power circuit
[Icw] rated short-time withstand current :
80 A - 1 s for signalling circuit
[Icw] rated short-time withstand current :
80 A 122 °F (50 °C) - 10 s for power circuit
[Icw] rated short-time withstand current :
85 A 122 °F (50 °C) - 5 s for power circuit
[Icw] rated short-time withstand current :
90 A - 500 ms for signalling circuit
[Icw] rated short-time withstand current :
90 A 122 °F (50 °C) - 1 s for power circuit
[Ie] rated operational current :
20 A (at
[Ie] rated operational current :
9 A (at
[Ith] conventional free air thermal current :
10 A (at 122 °F (50 °C)) for signalling circuit
[Ith] conventional free air thermal current :
20 A (at 140 °F (60 °C)) for power circuit
[Uc] control circuit voltage :
24 V DC
[Ue] rated operational voltage :
Power circuit 690 V AC 50/60 Hz
[Ue] rated operational voltage :
Signalling circuit
[Ui] rated insulation voltage :
Power circuit 600 V CSA C22.2 No 14
[Ui] rated insulation voltage :
Power circuit 600 V UL 508
[Ui] rated insulation voltage :
Power circuit 690 V IEC 60947-4-1
[Ui] rated insulation voltage :
Signalling circuit 600 V CSA C22.2 No 14
[Ui] rated insulation voltage :
Signalling circuit 600 V UL 508
[Ui] rated insulation voltage :
Signalling circuit 690 V IEC 60947-4-1
[Ui] rated insulation voltage :
Signalling circuit 690 V IEC 60947-5-1
[Uimp] rated impulse withstand voltage :
8 kV
Application :
Control
Associated Fuse Rating :
25 A aM for power circuit
Associated Fuse Rating :
25 A gG at
auxiliary contact composition :
1 NO
auxiliary contacts type :
Instantaneous 1 NO
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
233
contactor application :
Motor control
contactor application :
Resistive load
control circuit type :
DC standard
control circuit voltage limits :
Drop-out: 0.1...0.75 Uc (at
control circuit voltage limits :
Operational: 0.8...1.15 Uc (at
Depth :
2.2 in (57 mm)
Device Short Name :
LP2K
Electrical Durability :
0.02 Mcycles 54 A AC-4
Electrical Durability :
0.16 Mcycles 20 A AC-1
Electrical Durability :
1.3 Mcycles 9 A AC-3
Electrical Durability :
1.3 Mcycles 9 A AC-3e
Final Result for Flywheel performance tracking :
Non Flywheel
Flame Retardance :
V1 conforming to UL 94
Global Keywords :
2NO auxiliary contact
Global Keywords :
AC-3
Global Keywords :
Built-in auxiliary contact
Global Keywords :
Combination of contactors
Global Keywords :
DC coil
Global Keywords :
LP2K
Global Keywords :
Mechanical interlock
Global Keywords :
Motor control
Global Keywords :
Reversing contactor
Global Keywords :
Screw clamp terminals
Global Keywords :
TeSys K
Global warming ; Total life cycle? :
233 kg CO2 eq.
Heat Dissipation :
3 W
Height :
2.3 in (58 mm)
Hold-In Power Consumption In W :
3 W 68 °F (20 °C)
Inrush Power In W :
3 W 68 °F (20 °C))
insulation resistance :
> 10 MOhm for signalling circuit
interlocking type :
Mechanical
IP Degree of Protection :
IP20 VDE 0106
Manufacturer :
Schneider Electric
maximum operating rate :
3600 cyc/h
Mechanical Durability :
5 Mcycles
minimum switching current :
5 mA for signalling circuit
minimum switching voltage :
17 V for signalling circuit
motor power kW :
4 kW 380...415 V AC 50/60 Hz
motor power kW :
4 kW 440/690 V AC 50/60 Hz
Mounting Support :
Plate
Mounting Support :
Rail
Net Weight :
1.06 lb(US) (0.48 kg)
non overlap distance :
0.02 in (0.5 mm)
Number of Units in Package 2 :
20
Overvoltage Category :
III
Package 2 GTIN :
43389110499474
Package 2 Height :
5.91 in (15.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
20.507 lb(US) (9.302 kg)
Package 2 width :
11.81 in (30.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
Yes
pole contact composition :
3 NO
Product Certifications :
CB Scheme
Product Certifications :
CCC
Product Certifications :
CE
Product Certifications :
CSA
Product Certifications :
EAC
Product Certifications :
UKCA
Product Certifications :
UL
Product Name :
TeSys K
Product Or Component Type :
Reversing contactor
Protective Treatment :
TC DIN 50016
Protective Treatment :
TC IEC 60068
Range :
TeSys
rated breaking capacity :
110 A at 415 V conforming to IEC 60947
rated breaking capacity :
110 A at 440 V conforming to IEC 60947
rated breaking capacity :
80 A at 500 V conforming to IEC 60947
REACh free of SVHC :
Yes
Standards :
EN/IEC 60947-4-1
Standards :
GB/T 14048.4
Standards :
JIS C8201-4-1
Standards :
UL 60947-4-1
Sustainable packaging :
Yes
Take-back :
No
Temperature Ambient Operating Range :
-13…122 °F (-25…50 °C)
Temperature Shipping and Storage Range :
-58…176 °F (-50…80 °C)
Toxic heavy metal free :
Yes
Type Of Network :
3P
Unit Type of Package 2 :
S02
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
utilisation category :
AC-1
utilisation category :
AC-3
utilisation category :
AC-3e
utilisation category :
AC-4
Volume of Package 2 :
18000.000 cm3
Warranty :
18 months
Width :
3.5 in (90 mm)

No Reviews Yet

Write a Review