Power base TeSys U | Component type : Non reversing power base | Poles description : 3P | Conventional free air thermal current : 12 A | Utilisation category : AC-44, AC-43, AC-41 | Auxiliary contact composition : 1 NO + 1 NC | Rated operational voltage : 230 V, 440 V, 500 V, 690 V | Network frequency : 40...60 Hz | Rated operational current : 12 A at
- [Ics] rated service breaking capacity : 10 kA 500 V~~
- [Ics] rated service breaking capacity : 4 kA 690 V
- [Ics] rated service breaking capacity : 50 kA 230 V
- [Ics] rated service breaking capacity : 50 kA 440 V
- [Ie] rated operational current : 12 A
- [Ie] rated operational current : 12 A 500 V
- [Ie] rated operational current : 9 A 690 V
- [Ith] conventional free air thermal current : 12 A
- [Uc] control circuit voltage : 110...220 V DC
- [Uc] control circuit voltage : 110...240 V AC 50/60 Hz
- [Uc] control circuit voltage : 24 V AC 50/60 Hz
- [Uc] control circuit voltage : 24 V DC
- [Uc] control circuit voltage : 48...72 V AC 50/60 Hz
- [Uc] control circuit voltage : 48...72 V DC
- [Ue] rated operational voltage : 690 V AC power circuit
- [Ui] rated insulation voltage : 600 V CSA C22.2 No 60947-4-1
- [Ui] rated insulation voltage : 600 V UL 60947-4-1
- [Ui] rated insulation voltage : 690 V IEC 60947-6-2 3)
- [Uimp] rated impulse withstand voltage : 6 kVIEC 60947-6-2
- Ambient Air Temperature For Operation : -13…140 °F (-25…60 °C) with LUCM
- Ambient Air Temperature For Operation : -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD
- Application : Motor control
- Application : Motor protection
- auxiliary contact composition : 1 NO + 1 NC
- auxiliary contacts type : Linked contacts 1 NO + 1 NC) IEC 60947-4-1
- auxiliary contacts type : Mirror contact 1 NC) IEC 60947-1
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 25
- Connections - Terminals : Control circuit screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end
- Connections - Terminals : Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end
- Connections - Terminals : Control circuit screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²) rigid
- Connections - Terminals : Control circuit screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²) flexible with cable end
- Connections - Terminals : Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) flexible without cable end
- Connections - Terminals : Control circuit screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²) rigid
- Connections - Terminals : Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) flexible with cable end
- Connections - Terminals : Power circuit screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) rigid
- Connections - Terminals : Power circuit screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) flexible without cable end
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) flexible without cable end
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) flexible with cable end
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.009 in² (1…6 mm²) rigid
- Depth : 5.0 in (126 mm)
- Device Short Name : LUB
- Final Result for Flywheel performance tracking : Non Flywheel
- fire resistance : 1202 °F (650 °C) IEC 60695-2-12
- fire resistance : 1760 °F (960 °C) parts supporting live components IEC 60695-2-12
- Fixing Mode : Clipped (DIN rail)
- Fixing Mode : Screw-fixed (plate)
- Global Keywords : 1 direction
- Global Keywords : LUB
- Global Keywords : Modular base
- Global Keywords : Motor control
- Global Keywords : Motor protection
- Global Keywords : Non reverser
- Global Keywords : Standard power base
- Global Keywords : Starter controller
- Global Keywords : TeSys Ultra
- Global warming ; Total life cycle? : 25 kg CO2 eq.
- Halogen content performance : Product contains halogen above thresholds
- Heat Dissipation : 1.7 W control circuit with LUCM
- Heat Dissipation : 2 W control circuit with LUCA, LUCB, LUCC, LUCD
- Height : 6.06 in (154 mm)
- immunity to microbreaks : 3 ms control circuit
- immunity to radioelectric fields : 10 V IEC 61000-4-6
- immunity to voltage dips : 70 % / 500 ms IEC 61000-4-11
- Indivisible Sale Qty : 1
- IP Degree of Protection : IP20 IEC 60947-1 front panel and wired terminals)
- IP Degree of Protection : IP20 IEC 60947-1 other faces)
- IP Degree of Protection : IP40 IEC 60947-1 front panel outside connection zone)
- Manufacturer : Schneider Electric
- maximum operating rate : 3600 cyc/h
- Mechanical Durability : 15 Mcycles
- Net Weight : 2.0 lb(US) (0.9 kg)
- Network Frequency : 40...60 Hz
- non-dissipating shock wave : 1 kV serial mode 24...240 V AC IEC 60947-6-2
- non-dissipating shock wave : 1 kV serial mode 48...220 V DC IEC 60947-6-2
- non-dissipating shock wave : 2 kV common mode 24...240 V AC IEC 60947-6-2
- non-dissipating shock wave : 2 kV common mode 48...220 V DC IEC 60947-6-2
- Number of Units in Package 2 : 10
- Number of Units in Package 3 : 160
- Operating Altitude : 6561.68 ft (2000 m)
- Operating Time : 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit
- Operating Time : 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit
- Operating Time : 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit
- Operating Time : 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit
- Operating Time : 75 ms closing with LUCM control circuit
- Package 2 GTIN : 43389110362778
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 19.176 lb(US) (8.698 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 325.552 lb(US) (147.668 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- Product Certifications : ASEFA
- Product Certifications : ATEX
- Product Certifications : CCC
- Product Certifications : CE
- Product Certifications : CSA
- Product Certifications : EAC
- Product Certifications : Marine
- Product Certifications : UL
- Product Name : TeSys Ultra
- Product Or Component Type : Non reversing power base
- Protective Treatment : TH IEC 60068
- PVC free : Yes
- Range : TeSys
- REACh free of SVHC : Yes
- Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2
- Resistance To Electrostatic Discharge : 8 kV 4 on contact IEC 61000-4-2
- resistance to fast transients : 2 kV 3 serial link IEC 61000-4-4
- resistance to fast transients : 4 kV 4 all circuits except for serial link IEC 61000-4-4
- resistance to radiated fields : 9.1 V/m (10 V/m) 3 IEC 61000-4-3
- safe separation of circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N
- safe separation of circuit : 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
- safety reliability level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- safety reliability level : B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- SCIP Number : 61f5a085-dfde-4214-b2cf-ba3cfe0c33b4
- shock resistance : 10 gn power poles open IEC 60068-2-27
- shock resistance : 15 gn power poles closed IEC 60068-2-27
- Standards : CSA C22.2 No 60947-4-1, with phase barrier
- Standards : EN 60947-6-2
- Standards : IEC 60947-6-2
- Standards : UL 60947-4-1, with phase barrier
- suitability for isolation : Yes
- Sustainable packaging : Yes
- Take-back : No
- Temperature Shipping and Storage Range : -40…185 °F (-40…85 °C)
- Tightening Torque : Power circuit: 16.8…22.1 lbf.in (1.9…2.5 N.m) flat screwdriver 0.2 in (6 mm)
- Toxic heavy metal free : Yes
- Type Of Network : 3P
- typical current consumption : 130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 150 mA 24 V DC I maximum while closing with LUCM
- typical current consumption : 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 35 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 35 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 35 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 35 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
- typical current consumption : 70 mA 24 V DC I rms sealed with LUCM
- Unit Type of Package 2 : S02
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39121521
- UNSPSC Classification v23 : 39121521
- utilisation category : AC-41
- utilisation category : AC-43
- utilisation category : AC-44
- vibration resistance : 2 gn 5…300 Hz) power poles open IEC 60068-2-27
- vibration resistance : 4 gn 5…300 Hz) power poles closed IEC 60068-2-27
- Volume of Package 2 : 18000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Width : 1.8 in (45 mm)