REVERSING CONTACTOR 575VAC 25A IEC | Utilisation category : AC-1 | Poles description : 4P | Power pole contact composition : 4 NO | Control circuit voltage : 120 V AC 50/60 Hz | Rated operational current : 25 A | Auxiliary contact composition : 1 NO + 1 NC
- [Icw] rated short-time withstand current : 100 A - 1 s for signalling circuit~~
- [Icw] rated short-time withstand current : 105 A 104 °F (40 °C) - 10 s for power circuit
- [Icw] rated short-time withstand current : 120 A - 500 ms for signalling circuit
- [Icw] rated short-time withstand current : 140 A - 100 ms for signalling circuit
- [Icw] rated short-time withstand current : 210 A 104 °F (40 °C) - 1 s for power circuit
- [Icw] rated short-time withstand current : 30 A 104 °F (40 °C) - 10 min for power circuit
- [Icw] rated short-time withstand current : 61 A 104 °F (40 °C) - 1 min for power circuit
- [Ie] rated operational current : 25 A (at
- [Ith] conventional free air thermal current : 10 A (at 140 °F (60 °C)) for signalling circuit
- [Ith] conventional free air thermal current : 25 A (at 140 °F (60 °C)) for power circuit
- [Uc] control circuit voltage : 120 V AC 50/60 Hz
- [Ue] rated operational voltage : Power circuit
- [Ui] rated insulation voltage : Power circuit 600 V CSA
- [Ui] rated insulation voltage : Power circuit 600 V UL
- [Ui] rated insulation voltage : Power circuit 690 V IEC 60947-4-1
- [Ui] rated insulation voltage : Signalling circuit 600 V CSA
- [Ui] rated insulation voltage : Signalling circuit 600 V UL
- [Ui] rated insulation voltage : Signalling circuit 690 V IEC 60947-1
- [Uimp] rated impulse withstand voltage : 6 kV IEC 60947
- Ambient Air Temperature For Operation : 140…158 °F (60…70 °C) with derating
- Ambient Air Temperature For Operation : -40…140 °F (-40…60 °C)
- Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1
- Associated Fuse Rating : 25 A gG at
- Associated Fuse Rating : 40 A gG at
- auxiliary contact composition : 1 NO + 1 NC
- auxiliary contacts type : Mechanically linked 1 NO + 1 NC IEC 60947-5-1
- auxiliary contacts type : Mirror contact 1 NC IEC 60947-4-1
- average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 54
- climatic withstand : IACS E10
- climatic withstand : IEC 60947-1 Annex Q category D
- coil technology : Without built-in suppressor module
- Connections - Terminals : Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
- Connections - Terminals : Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
- Connections - Terminals : Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid
- Connections - Terminals : Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
- Connections - Terminals : Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
- Connections - Terminals : Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid
- Connections - Terminals : Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
- Connections - Terminals : Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
- Connections - Terminals : Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
- Connections - Terminals : Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid
- contact compatibility : M6
- contactor application : Resistive load
- control circuit type : AC 50/60 Hz
- control circuit voltage limits : 0.3...0.6 Uc (-40…140 °F (-40…60 °C)):drop-out AC 50/60 Hz
- control circuit voltage limits : 0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz
- control circuit voltage limits : 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz
- Depth : 3.5 in (90 mm)
- Device Presentation : Preassembled, with prewired power connections
- Device Short Name : LC2D
- Electrical Durability : 0.8 Mcycles 25 A AC-1
- Final Result for Flywheel performance tracking : Non Flywheel
- fire resistance : 1562 °F (850 °C) IEC 60695-2-1
- Flame Retardance : V1 conforming to UL 94
- Global Keywords : 4-pole reversing contactor
- Global Keywords : AC coil
- Global Keywords : AC-3
- Global Keywords : Built-in auxiliary contact
- Global Keywords : Iec contactor
- Global Keywords : LC2D
- Global Keywords : Mechanical interlock
- Global Keywords : Motor control
- Global Keywords : Motor switching
- Global Keywords : Open style
- Global Keywords : Pre-wired connections
- Global Keywords : Reversing contactor
- Global Keywords : Reversing power contactor
- Global Keywords : Screw clamp terminals
- Global Keywords : TeSys D
- Global warming ; Total life cycle? : 54 kg CO2 eq.
- Heat Dissipation : 2…3 W 50/60 Hz
- Height : 3.3 in (85 mm)
- Hold-In Power Consumption In Va : 7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
- Hold-In Power Consumption In Va : 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
- inrush power in VA : 70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
- inrush power in VA : 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
- insulation resistance : > 10 MOhm for signalling circuit
- interlocking type : Mechanical
- IP Degree of Protection : IP20 front face IEC 60529
- Irms rated making capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1
- Irms rated making capacity : 250 A at 440 V for power circuit conforming to IEC 60947
- Irms rated making capacity : 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Manufacturer : Schneider Electric
- maximum operating rate : 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability : 15 Mcycles
- Mechanical Robustness : Shocks contactor closed15 Gn for 11 ms
- Mechanical Robustness : Shocks contactor open10 Gn for 11 ms
- Mechanical Robustness : Vibrations contactor closed4 Gn, 5...300 Hz
- Mechanical Robustness : Vibrations contactor open2 Gn, 5...300 Hz
- minimum switching current : 5 mA for signalling circuit
- minimum switching voltage : 17 V for signalling circuit
- Mounting Support : Plate
- Mounting Support : Rail
- Net Weight : 1.61 lb(US) (0.73 kg)
- non-overlap time : 1.5 ms on de-energisation between NC and NO contact
- non-overlap time : 1.5 ms on energisation between NC and NO contact
- Number of Units in Package 2 : 5
- Number of Units in Package 3 : 80
- Operating Altitude : 0...9842.52 ft (0...3000 m)
- Operating Time : 12...22 ms closing
- Operating Time : 4...19 ms opening
- Overvoltage Category : III
- Package 2 GTIN : 43389110515884
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 10.119 lb(US) (4.590 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 30.31 in (77.000 cm)
- Package 3 Length : 23.62 in (60.000 cm)
- Package 3 Weight : 188.760 lb(US) (85.620 kg)
- Package 3 width : 31.50 in (80.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- pole contact composition : 4 NO
- Pollution Degree : 3
- power dissipation per pole : 1.56 W AC-1
- Product Certifications : BV
- Product Certifications : CB
- Product Certifications : CCC
- Product Certifications : CSA
- Product Certifications : DNV
- Product Certifications : GL
- Product Certifications : GOST
- Product Certifications : LROS (Lloyds register of shipping)
- Product Certifications : RINA
- Product Certifications : UKCA
- Product Certifications : UL
- Product Name : TeSys D
- Product Name : TeSys Deca
- Product Or Component Type : Changeover contactor
- protective cover : With
- Protective Treatment : TH IEC 60068-2-30
- PVC free : Yes
- Range : TeSys
- Range : TeSys Deca
- rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947
- REACh free of SVHC : Yes
- safety reliability level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- safety reliability level : B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- signalling circuit frequency : 25...400 Hz
- Standards : CSA C22.2 No 60947-4-1
- Standards : CSA C22.2 No 60947-5-1
- Standards : EN 60947-4-1
- Standards : EN 60947-5-1
- Standards : GB/T 14048.4
- Standards : IEC 60947-4-1
- Standards : IEC 60947-5-1
- Standards : UL 60947-4-1
- Standards : UL 60947-5-1
- Sustainable packaging : Yes
- Take-back : No
- Temperature Shipping and Storage Range : -76…176 °F (-60…80 °C)
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
- Tightening Torque : Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
- Tightening Torque : Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
- Tightening Torque : Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
- Tightening Torque : Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
- Toxic heavy metal free : Yes
- Type Of Network : 4P
- Unit Type of Package 2 : S02
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39121529
- UNSPSC Classification v23 : 39121529
- utilisation category : AC-1
- Volume of Package 2 : 18000.000 cm3
- Volume of Package 3 : 369600.000 cm3
- Warranty : 18 months
- Width : 3.5 in (90 mm)