zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

LC1DT40G7

$271.14
(No reviews yet) Write a Review
SKU:
LC1DT40G7
Adding to cart… The item has been added
TeSys D Contactor |Number of Poles: 4-Poles|Pole Contact Composition: 4 NO|Rated Operational Current: 40A|Control Circuit Voltage: 120V AC 50/60 Hz|Non-Reversing
[Icw] rated short-time withstand current :
100 A - 1 s for signalling circuit~~
[Icw] rated short-time withstand current :
120 A - 500 ms for signalling circuit
[Icw] rated short-time withstand current :
120 A 104 °F (40 °C) - 1 min for power circuit
[Icw] rated short-time withstand current :
140 A - 100 ms for signalling circuit
[Icw] rated short-time withstand current :
240 A 104 °F (40 °C) - 10 s for power circuit
[Icw] rated short-time withstand current :
380 A 104 °F (40 °C) - 1 s for power circuit
[Icw] rated short-time withstand current :
50 A 104 °F (40 °C) - 10 min for power circuit
[Ie] rated operational current :
40 A (at
[Ith] conventional free air thermal current :
10 A (at 140 °F (60 °C)) for signalling circuit
[Ith] conventional free air thermal current :
40 A (at 140 °F (60 °C)) for power circuit
[Uc] control circuit voltage :
120 V AC 50/60 Hz
[Ue] rated operational voltage :
Power circuit
[Ui] rated insulation voltage :
Power circuit 600 V CSA
[Ui] rated insulation voltage :
Power circuit 600 V UL
[Ui] rated insulation voltage :
Power circuit 690 V IEC 60947-4-1
[Ui] rated insulation voltage :
Signalling circuit 600 V CSA
[Ui] rated insulation voltage :
Signalling circuit 600 V UL
[Ui] rated insulation voltage :
Signalling circuit 690 V IEC 60947-1
[Uimp] rated impulse withstand voltage :
6 kV IEC 60947
Associated Fuse Rating :
40 A gG at
Associated Fuse Rating :
63 A gG at
auxiliary contact composition :
1 NO + 1 NC
auxiliary contacts type :
Mirror contact 1 NC IEC 60947-4-1
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
209
climatic withstand :
IACS E10 exposure to damp heat
contact compatibility :
M6
contactor application :
Resistive load
control circuit type :
AC 50/60 Hz
Depth :
3.9 in (99 mm)
Device Short Name :
LC1D
Electrical Durability :
1.4 Mcycles 40 A AC-1
Final Result for Flywheel performance tracking :
Non Flywheel
Flame Retardance :
V1 conforming to UL 94
Global Keywords :
4NO
Global Keywords :
4-pole contactor
Global Keywords :
AC coil
Global Keywords :
AC-1
Global Keywords :
Built-in auxiliary contacts
Global Keywords :
Electrical load control
Global Keywords :
Electrical load switching
Global Keywords :
LC1DT
Global Keywords :
Magnetic contactor
Global Keywords :
Power contactor
Global Keywords :
Screw clamp terminals
Global Keywords :
TeSys D
Global warming ; Total life cycle? :
209 kg CO2 eq.
Heat Dissipation :
2…3 W at 50/60 Hz
Height :
3.6 in (91 mm)
Hold-In Power Consumption In Va :
7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-In Power Consumption In Va :
7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
insulation resistance :
> 10 MOhm for signalling circuit
IP Degree of Protection :
IP20 front face IEC 60529
Manufacturer :
Schneider Electric
maximum operating rate :
3600 cyc/h at 60 °C
Mechanical Durability :
15 Mcycles
Mechanical Robustness :
Shocks contactor open 8 Gn for 11 ms)
minimum switching current :
5 mA for signalling circuit
minimum switching voltage :
17 V for signalling circuit
Mounting Support :
Plate
Mounting Support :
Rail
Number of Units in Package 2 :
15
Number of Units in Package 3 :
240
Operating Altitude :
0...9842.52 ft (0...3000 m)
Operating Time :
12...22 ms closing
Operating Time :
4...19 ms opening
Overvoltage Category :
III
Package 2 GTIN :
13389110339564
Package 2 Height :
5.91 in (15.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
16.413 lb(US) (7.445 kg)
Package 2 width :
11.81 in (30.000 cm)
Package 3 Height :
30.31 in (77.000 cm)
Package 3 Length :
31.50 in (80.000 cm)
Package 3 Weight :
282.412 lb(US) (128.100 kg)
Package 3 width :
23.62 in (60.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
No
Permissible Ambient Air Temperature Around The Dev :
140…158 °F (60…70 °C) with derating
Permissible Ambient Air Temperature Around The Dev :
-40…140 °F (-40…60 °C)
pole contact composition :
4 NO
Pollution Degree :
3
power dissipation per pole :
3.2 W AC-1
Product Certifications :
BV
Product Certifications :
CCC
Product Certifications :
CSA
Product Certifications :
DNV
Product Certifications :
GL
Product Certifications :
GOST
Product Certifications :
LROS (Lloyds register of shipping)
Product Certifications :
RINA
Product Certifications :
UL
Product Or Component Type :
Contactor
protective cover :
With
Protective Treatment :
THIEC 60068-2-30
PVC free :
Yes
Range :
TeSys
Range :
TeSys Deca
REACh free of SVHC :
Yes
signalling circuit frequency :
25...400 Hz
Standards :
CSA C22.2 No 14
Standards :
EN 60947-4-1
Standards :
EN 60947-5-1
Standards :
IEC 60335-1
Standards :
IEC 60947-4-1
Standards :
IEC 60947-5-1
Standards :
UL 508
Take-back :
No
Type Of Network :
4P
Unit Type of Package 2 :
S02
Unit Type of Package 3 :
P06
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
utilisation category :
AC-1
Volume of Package 2 :
18000.000 cm3
Volume of Package 3 :
369600.000 cm3
Warranty :
18 months
Width :
1.8 in (45 mm)

No Reviews Yet