TeSys D - time delay auxiliary contact block - 1 NO + 1 NC screw clamp terminals
- [Ie] rated operational current : 0.1 A at 600 V DC-13~~
- [Ie] rated operational current : 0.55 A at 125 V DC-13
- [Ie] rated operational current : 1.04 A at 690 V AC-15
- [Ie] rated operational current : 6 A at 120 V AC-15
- [Ith] conventional free air thermal current : 10 A (at 140 °F (60 °C))
- [Ue] rated operational voltage : 690 V AC 25...400 Hz
- [Ui] rated insulation voltage : 600 V CSA C22.2 No 60947-5-1
- [Ui] rated insulation voltage : 600 V UL 60947-5-1
- [Ui] rated insulation voltage : 690 V IEC 60947-5-1
- auxiliary contacts operation : Time delay
- Brand : Schneider Electric
- By Schneider : Yes
- California proposition 65 : WARNING: Cancer - www.P65Warnings.ca.gov
- Carbon footprint (kg CO2 eq, Total Life cycle) : 4
- Circularity Profile : No need of specific recycling operations
- Color : Dark grey
- Connections - Terminals : screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
- Connections - Terminals : screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)flexible without cable end
- Connections - Terminals : screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)rigid
- Connections - Terminals : screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
- Connections - Terminals : screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible without cable end
- Connections - Terminals : screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)rigid
- Connections - Terminals : Screw clamp terminals
- Depth : 2.4 in (61 mm)
- Environmental Characteristic : Normal environment
- Final Result for Flywheel performance tracking : Non Flywheel
- Global Keywords : Add-on contact block
- Global Keywords : Auxiliary contact block
- Global Keywords : Front mounting
- Global Keywords : LADT
- Global Keywords : Off-delay contact
- Global Keywords : TeSys D
- Global Keywords : Time delay contact
- Global warming ; Total life cycle? : 4 kg CO2 eq.
- Height : 1.9 in (48 mm)
- insulation resistance : > 10 MOhm
- IP Degree of Protection : IP20 conforming to IEC 60529
- Irms rated making capacity : 140 A at
- Irms rated making capacity : 250 A at
- Manufacturer : Schneider Electric
- Mechanical Durability : 5 Mcycles
- minimum switching current : 5 mA
- minimum switching voltage : 17 V
- Mounting Location : Front
- non-overlap time : 1.5 ms on de-energisation no overlap between NC and NO contact
- non-overlap time : 1.5 ms on energisation no overlap between NC and NO contact
- Number of Units in Package 2 : 140
- Number of Units in Package 3 : 1120
- Operating Altitude : 9842.52 ft (3000 m)
- Package 2 GTIN : 43389110385029
- Package 2 Height : 11.81 in (30.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 24.291 lb(US) (11.018 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 223.417 lb(US) (101.340 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- permissible short-time rating : 100 A 140 °F (60 °C) 1 s
- permissible short-time rating : 120 A 140 °F (60 °C) 500 ms
- permissible short-time rating : 140 A 140 °F (60 °C) 100 ms
- pole contact composition : 1 NO + 1 NC
- Product Certifications : CCC
- Product Certifications : CSA
- Product Certifications : EAC
- Product Certifications : IECEE CB Scheme
- Product Certifications : UKCA
- Product Certifications : UL
- Product Name : TeSys Deca
- Product Or Component Type : Time delay auxiliary contact block
- Protection Type : GG fuse 10 A
- Protective Treatment : TH IEC 60068
- PVC free : Yes
- Range : TeSys
- Range : TeSys Deca
- Range Compatibility : TeSys Deca CAD
- Range Compatibility : TeSys Deca LC1D
- Range Compatibility : TeSys F CR1F
- Range Compatibility : TeSys F LC1F
- SCIP Number : 0ec600a1-51d5-4e42-a756-c9f6cbd40f70
- Shielding continuity terminal : Without
- Standards : CSA C22.2 No 60947-5-1
- Standards : EN 50012
- Standards : EN/IEC 60947-5-1
- Standards : GB/T 14048.5
- Standards : IEC 60335-1:Clause 30.2
- Standards : IEC 60335-2-40:Annex JJ
- Standards : UL 60335-2-40:Annex JJ
- Standards : UL 60947-5-1
- Sustainable packaging : Yes
- Take-back : No
- Temperature Ambient Operating Range : -40…158 °F (-40…70 °C)
- Temperature Shipping and Storage Range : -76…176 °F (-60…80 °C)
- Tightening Torque : 15.05 lbf.in (1.7 N.m) flat Ø 6 mm
- Tightening Torque : 15.05 lbf.in (1.7 N.m) Philips No 2
- Tightening Torque : 15.05 lbf.in (1.7 N.m) pozidriv No 2
- time delay range : 0.3...3 s
- timer type : On delay
- Unit Type of Package 2 : S03
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39121529
- UNSPSC Classification v23 : 39121529
- Volume of Package 2 : 36000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Width : 1.7 in (44 mm)