TeSys U Standard Control Unit|Thermal Overload Class: Class 10|Thermal Protection Adjustment Range: 8-32A|Control Circuit Voltage: 24V AC|Mounting Mode: Plug-in|Mounting Location: Front side|Load Type: 3-Phase Motor; cooling: self-cooled|Degree of Protection: IP20, IP40
- [Uc] control circuit voltage : 24 V AC~~
- [Ue] rated operational voltage : 690 V AC
- [Ui] rated insulation voltage : 600 V CSA C22.2 No 60947-4-1
- [Ui] rated insulation voltage : 600 V UL 60947-4-1
- [Ui] rated insulation voltage : 690 V IEC 60947-6-2
- [Uimp] rated impulse withstand voltage : 6 kV IEC 60947-6-2
- Ambient Air Temperature For Operation : -13…158 °F (-25…70 °C)
- Application : Motor control
- Application : Motor protection
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 17
- control circuit voltage limits : 14.5 V AC 24 V drop-out
- control circuit voltage limits : 20...26.5 V AC 24 V in operation
- Depth : 2.4 in (60 mm)
- Device Short Name : LUCA
- Final Result for Flywheel performance tracking : Non Flywheel
- fire resistance : 1202 °F (650 °C) IEC 60695-2-12
- fire resistance : 1760 °F (960 °C) parts supporting live components IEC 60695-2-12
- Fixing Mode : Plug-in (front face)
- Function Available : Earth fault protection
- Function Available : Manual reset
- Function Available : Protection against overload and short-circuit
- Function Available : Protection against phase failure and phase imbalance
- Global Keywords : Control unit
- Global Keywords : Insulation
- Global Keywords : LUCA
- Global Keywords : Motor protection
- Global Keywords : Phase loss
- Global Keywords : Phase unbalance
- Global Keywords : Standard unit
- Global Keywords : TeSys Ultra
- Global Keywords : Thermal class 10
- Global Keywords : Thermal magnetic protection
- Global warming ; Total life cycle? : 17 kg CO2 eq.
- Halogen content performance : Halogen free plastic parts product
- Heat Dissipation : 3 W control circuit with LUB32
- Heat Dissipation : 3 W control circuit with LUB38
- Height : 2.6 in (66 mm)
- immunity to microbreaks : 3 ms
- immunity to radioelectric fields : 10 V IEC 61000-4-6
- immunity to voltage dips : 70 % / 500 ms IEC 61000-4-11
- IP Degree of Protection : IP20 front panel and wired terminals IEC 60947-1
- IP Degree of Protection : IP20 other faces IEC 60947-1
- IP Degree of Protection : IP40 front panel outside connection zone IEC 60947-1
- Load Type : 3-phase motor self-cooled
- Manufacturer : Schneider Electric
- motor power kW : 15 kW 400...440 V AC 50/60 Hz
- motor power kW : 15 kW 500 V AC 50/60 Hz
- motor power kW : 18.5 kW 690 V AC 50/60 Hz
- Net Weight : 0.298 lb(US) (0.135 kg)
- Network Frequency : 40...60 Hz
- Number of Units in Package 2 : 23
- Operating Altitude : 6561.68 ft (2000 m)
- Operating Time : 35 ms opening with LUB32 control circuit
- Operating Time : 35 ms opening with LUB38 control circuit
- Operating Time : 70 ms closing with LUB32 control circuit
- Operating Time : 70 ms closing with LUB38 control circuit
- Package 2 GTIN : 43389110363935
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 6.878 lb(US) (3.120 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- phase failure sensitivity : Yes
- Product Certifications : ASEFA
- Product Certifications : ATEX
- Product Certifications : CCC
- Product Certifications : CE
- Product Certifications : CSA
- Product Certifications : EAC
- Product Certifications : Marine
- Product Certifications : UL
- Product Compatibility : Power base LUB32
- Product Compatibility : Power base LUB320
- Product Compatibility : Power base LUB38
- Product Compatibility : Power base LUB380
- Product Compatibility : Reversing contactor breaker LU2B32B
- Product Name : TeSys Ultra
- Product Or Component Type : Standard control unit
- Product Specific Application : Basic protection requirements for motor starters: overload and short-circuit
- Protective Treatment : TH IEC 60068
- PVC free : Yes
- Range : TeSys
- Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2
- Resistance To Electrostatic Discharge : 8 kV 4 on contact IEC 61000-4-2
- resistance to fast transients : 2 kV 3 serial link IEC 61000-4-4
- resistance to fast transients : 4 kV 4 all circuits except for serial link IEC 61000-4-4
- resistance to radiated fields : 9.1 V/m (10 V/m) 3 IEC 61000-4-3
- safe separation of circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1
- safe separation of circuit : 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- SCIP Number : 801f74dc-0e56-49a3-aaeb-b34d99dcea36
- shock resistance : 10 gn power poles open IEC 60068-2-27
- shock resistance : 15 gn power poles closed IEC 60068-2-27
- Standards : CSA C22.2 No 60947-4-1, with phase barrier
- Standards : EN 60947-6-2
- Standards : IEC 60947-6-2
- Standards : UL 60947-4-1, with phase barrier
- Sustainable packaging : Yes
- Take-back : No
- Temperature Shipping and Storage Range : -40…185 °F (-40…85 °C)
- thermal overload class : Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2
- thermal overload class : Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
- thermal protection adjustment range : 8…32 A
- tripping threshold : 14.2 x Ir +/- 20 %
- typical current consumption : 220 mA 24 V AC I maximum while closing with LUB32
- typical current consumption : 220 mA 24 V AC I maximum while closing with LUB38
- typical current consumption : 90 mA 24 V AC I rms sealed with LUB32
- typical current consumption : 90 mA 24 V AC I rms sealed with LUB38
- Unit Type of Package 2 : S02
- UNSPSC Classification v19 : 43201542
- UNSPSC Classification v23 : 43201542
- utilisation category : AC-41
- utilisation category : AC-43
- utilisation category : AC-44
- vibration resistance : 2 gn 5…300 Hz power poles open IEC 60068-2-6
- vibration resistance : 4 gn 5…300 Hz power poles closed IEC 60068-2-6
- Volume of Package 2 : 18000.000 cm3
- Warranty : 18 months
- Width : 1.8 in (45 mm)