Zelio Control Relay|Network Number of Phases: 3 Phases|Relay Monitored Parameters: Phase sequence, Overvoltage and undervoltage detection, Phase failure detection| Measurement Range: 380-480V AC|Maximum Switching Voltage: 250V AC|Maximum Switching Current: 8A AC|Rated Supply Voltage: 380-480V AC|Output Contacts: 2 C/O|Mounting Position: Any|Connections - Terminals: Screw terminals|Status LED: LED yellow for relay ON, LED green for power ON|Degree of Protection: IP20 on terminals, IP40 on housing, IP50 on front panel, conforming to IEC 60529
- [Uc] control circuit voltage : 380...480 V~~
- [Us] rated supply voltage : self-powered
- Ambient Air Temperature For Operation : -4…122 °F (-20…50 °C) 60 Hz
- Ambient Air Temperature For Operation : -4…140 °F (-20…60 °C) 50 Hz AC/DC
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 95
- Circular Eligibility : Repack list
- Connections - Terminals : Screw connectors
- Connections - Terminals : Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
- Connections - Terminals : Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
- Connections - Terminals : Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- Connections - Terminals : Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
- Contacts Material : Cadmium free
- Contacts Type And Composition : 2 C/O
- control circuit voltage limits : - 20 % + 20 % Un
- dielectric test voltage : 2.5 kV AC 50 Hz, 1 min IEC 60255-27
- Electrical Durability : 100000 cycles
- Electromagnetic Compatibility : Conducted and radiated emissions class B conforming to CISPR 22
- Electromagnetic Compatibility : Conducted and radiated emissions class B group 1 conforming to CISPR 11
- Electromagnetic Compatibility : Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
- Electromagnetic Compatibility : Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
- Electromagnetic Compatibility : Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
- Electromagnetic Compatibility : Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
- Electromagnetic Compatibility : Emission standard for industrial environments conforming to IEC 61000-6-4
- Electromagnetic Compatibility : Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
- Electromagnetic Compatibility : Immunity for industrial environments conforming to IEC 61000-6-2
- Electromagnetic Compatibility : Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
- Electromagnetic Compatibility : Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
- Electromagnetic Compatibility : Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
- Electromagnetic Compatibility : Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
- Final Result for Flywheel performance tracking : Non Flywheel
- functionality : Overvoltage and undervoltage detection
- Global Keywords : 2 C/O Output Contacts
- Global Keywords : 22.5mm
- Global Keywords : 3-phase monitoring relay
- Global Keywords : DIN rail mounted
- Global Keywords : DPDT
- Global Keywords : Harmony Control
- Global Keywords : Overvoltage and undervoltage detection
- Global Keywords : Phase loss
- Global Keywords : Phase sequence
- Global Keywords : RM22
- Global Keywords : Schneider electric
- Global warming ; Total life cycle? : 95 kg CO2 eq.
- housing material : Self-extinguishing plastic
- Hysteresis : 2 % fixed selectable
- immunity to microbreaks : 10 ms
- insulation resistance : > 100 MOhm 500 V DC IEC 60255-27
- IP Degree of Protection : IP20 IEC 60529 terminals)
- IP Degree of Protection : IP40 IEC 60529 housing)
- IP Degree of Protection : IP50 IEC 60529 front panel)
- Line Rated Current : 8 A
- Manufacturer : Schneider Electric
- maximum measuring cycle : 150 ms measurement cycle as true rms value
- Maximum Switching Current : 8 A AC
- maximum switching voltage : 250 V AC
- Measurement Range : 380...480 V voltage AC
- Mechanical Durability : 10000000 cycles
- minimum switching current : 10 mA 5 V DC
- mounting position : Any position
- Mounting Support : 35 mm DIN rail conforming to IEC 60715
- Net Weight : 0.20 lb(US) (0.09 kg)
- nominal output current : 8 A
- Number of Units in Package 2 : 40
- Number of Units in Package 3 : 640
- output contacts : 2 C/O
- Override : With test button
- Overvoltage Category : III conforming to IEC 60664-1
- Overvoltage Category : III conforming to UL 508
- Package 2 GTIN : 43606480792197
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 10.344 lb(US) (4.692 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 178.707 lb(US) (81.060 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- Phase : 3 phase
- Pollution Degree : 3 IEC 60664-1
- Pollution Degree : 3 UL 508
- Power Consumption In Va : 15 VA 480 V AC 60 Hz
- Product Certifications : CCC
- Product Certifications : CE
- Product Certifications : CSA
- Product Certifications : EAC
- Product Certifications : GL
- Product Certifications : RCM
- Product Certifications : UL
- Product Or Component Type : 3-phase control relay
- Relative Humidity : 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30
- relay monitored parameters : Overvoltage and undervoltage detection
- relay monitored parameters : Phase failure detection
- relay monitored parameters : Phase sequence
- relay name : RM22TR
- Relay Type : Control relay
- Repeat Accuracy : +/- 0.5 % input and measurement circuit
- Repeat Accuracy : +/- 3 % time delay
- reset time : 1500 ms at maximum voltage
- run-up delay at power-up : 650 ms
- safety reliability data : B10d = 350000
- safety reliability data : MTTFd = 388.1 years
- SCIP Number : 3c095d35-159c-493c-8604-58788d456aa9
- setting accuracy of the switching threshold : +/- 10 % of the full scale
- setting accuracy of time delay : 10 P
- shock resistance : 15 gn 11 ms) not in operation IEC 60068-2-27
- shock resistance : 5 gn 11 ms) in operation IEC 60068-2-27
- Standards : IEC 60255-1
- Status Led : LED (Green) power ON
- Status Led : LED (Yellow) relay ON
- Supply Circuit Type : AC/DC
- Supply Frequency : 50...60 Hz +/- 10 %
- supply voltage limits : 304…576 V AC
- Sustainable packaging : Yes
- switching capacity in VA : 2000 VA
- Take-back : No
- Temperature Shipping and Storage Range : -40…158 °F (-40…70 °C)
- threshold adjustment voltage : 2...20 % of Un selected
- Tightening Torque : 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
- Unit Type of Package 2 : S02
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39122329
- UNSPSC Classification v23 : 39122329
- utilisation category : AC-1 IEC 60947-4-1
- utilisation category : AC-15 IEC 60947-5-1
- utilisation category : DC-1 IEC 60947-4-1
- utilisation category : DC-13 IEC 60947-5-1
- vibration resistance : 0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6
- vibration resistance : 0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6
- vibration resistance : 0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6
- vibration resistance : 1 gn 10…58.1 Hz) not in operation IEC 60068-2-6
- Voltage Range : 380...480 V phase to phase
- Volume of Package 2 : 18000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Width : 0.9 in (22.5 mm)