InRow RD, 600mm Air Cooled, 460-480V, 60Hz, with humidifier

$0.00
(No reviews yet) Write a Review
SKU:
ACRD601P
InRow RD, 600mm Air Cooled, 460-480V, 60Hz, with humidifier
acoustic level :
84 dBA
additional specification :
With humidity control
Air Discharge Patterns :
Horizontal
By Schneider :
Yes
Channel status :
Contact Sales
Color :
Black
Compressor Type :
Scroll
Condensate Pump Capacity :
32 Gal/hr(US) (0.1 m3/h)
Configurators/Selectors :
Cooling Solutions
Configurators/Selectors :
Large data centers
Configurators/Selectors :
Medium data centers
Configurators/Selectors :
Small data centers
curve equation :
Loss
curve fixed loss :
0.1397
curve load maximum :
100 %
curve proportional loss :
-0.2934
curve square loss :
0.6234
curve X-axis maximum :
100 %
curve X-axis minimum :
0 %
curve X-axis title :
Load
curve X-axis units :
Percentage
curve Y-axis maximum :
50 %
curve Y-axis minimum :
0 %
curve Y-axis title :
Loss
curve Y-axis units :
Percentage
Final Result for Connectable :
Not connectable
Final Result for Flywheel performance tracking :
Non Flywheel
Global Keywords :
600mm
Global Keywords :
Air-cooled CRAC
Global Keywords :
Humidifier
Global Keywords :
InRow RD
Global Keywords :
Row-based cooling
Humidification Value :
6.6 lb/hr (3.0 kg/hr)
Input Frequency :
60 Hz
Input Power :
20200 W
inrush current :
28 A
Intake Air :
Rear Return
Main Input Voltage :
460 V 3 phase
Main Input Voltage :
480 V 3 phase
Maximum Overcurrent Protection :
50 A
Minimum Circuit Amp Capacity :
37 A
Mounting Mode :
Not rack-mountable
Mounting Preference :
No preference
Net Weight :
886.3 lb(US) (402 kg)
number of input connectors :
1 Hard Wire 4-wire (3PH + G)
Number of Power Feeds :
1
number of rack unit :
42U
OEM :
APC
Operating Altitude :
0...10000 ft
Packaging made with recycled cardboard :
No
Packaging without single use plastic :
No
Piping Material :
Copper
Product Certifications :
CUL Listed
Product Certifications :
UL Listed
Provided Equipment :
Door key
Provided Equipment :
Installation guide
Provided Equipment :
Integrated network management
Provided Equipment :
Network Management Card
Provided Equipment :
Operations and maintenance manual
Provided Equipment :
User Manual
Relative Humidity :
5…95 %
Return pipe diameter :
0.75 in (19.05 mm)
Supply pipe diameter :
0.75 in (19.05 mm)
Take-back :
No
Temperature Ambient Operating Range :
-4…122 °F (-20…50 °C)