TeSys D Contactor |Number of Poles: 3-Poles|Pole Contact Composition: 3 NO|Rated Operational Current: 50A|Control Circuit Voltage: 480V AC 60 Hz|Non-Reversing
- [Ie] rated operational current : 50 A (at~~
- [Ie] rated operational current : 50 A (at
- [Ie] rated operational current : 80 A (at
- [Ith] conventional free air thermal current : 10 A (at 140 °F (60 °C)) for control circuit
- [Ith] conventional free air thermal current : 80 A (at 140 °F (60 °C)) for power circuit
- [Uc] control circuit voltage : 480 V AC 60 Hz
- [Ue] rated operational voltage : Power circuit
- [Ui] rated insulation voltage : Control circuit 600 V CSA
- [Ui] rated insulation voltage : Control circuit 600 V UL
- [Ui] rated insulation voltage : Control circuit 690 V IEC 60947-1
- [Ui] rated insulation voltage : Power circuit 600 V CSA
- [Ui] rated insulation voltage : Power circuit 600 V UL
- [Ui] rated insulation voltage : Power circuit 690 V IEC 60947-1
- [Uimp] rated impulse withstand voltage : 6 kV IEC 60947
- Associated Fuse Rating : 10 A gG for control circuit conforming to IEC 60947-5-1
- Associated Fuse Rating : 100 A gG at
- auxiliary contact composition : 1 NO + 1 NC
- auxiliary contacts type : Mechanically linked 1 NO + 1 NC IEC 60947-5-1
- auxiliary contacts type : Mirror contact 1 NC IEC 60947-4-1
- average impedance : 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 62
- Circularity Profile : No need of specific recycling operations
- climatic withstand : IACS E10 exposure to damp heat
- coil technology : Without built-in bidirectional peak limiting diode suppressor
- Connections - Terminals : Power circuit: connector 1 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: flexible with cable end
- Connections - Terminals : Power circuit: connector 1 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: solid with cable end
- Connections - Terminals : Power circuit: connector 2 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: flexible with cable end
- Connections - Terminals : Power circuit: connector 2 0.004…0.05 in² (2.5…35 mm²) - cable stiffness: solid with cable end
- contactor application : Motor control
- contactor application : Resistive load
- control circuit type : AC 60 Hz
- control circuit voltage limits : 0.3...0.6 Uc (140 °F (60 °C)):drop-out AC 60 Hz
- control circuit voltage limits : 0.85...1.1 Uc (140 °F (60 °C)):operational AC 60 Hz
- Depth : 4.7 in (119 mm)
- Device Short Name : LC1D
- Final Result for Flywheel performance tracking : Non Flywheel
- fire resistance : 1562 °F (850 °C) IEC 60695-2-1
- Flame Retardance : V1 conforming to UL 94
- Global Keywords : AC coil
- Global Keywords : AC control
- Global Keywords : CTR
- Global warming ; Total life cycle? : 62 kg CO2 eq.
- Heat Dissipation : 4…5 W at 50/60 Hz for control circuit
- Height : 4.8 in (122 mm)
- Hold-In Power Consumption In Va : 13 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
- Hold-In Power Consumption In Va : 15 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
- Indivisible Sale Qty : 1
- inrush power in VA : 140 VA cos phi 0.75 (at 68 °F (20 °C))
- inrush power in VA : 160 VA cos phi 0.75 (at 68 °F (20 °C))
- insulation resistance : > 10 MOhm for control circuit
- IP Degree of Protection : IP2x IEC 60529
- IP Degree of Protection : IP2x VDE 0106
- Irms rated making capacity : 140 A AC for control circuit conforming to IEC 60947-5-1
- Irms rated making capacity : 900 A at 440 V for power circuit conforming to IEC 60947
- Manufacturer : Schneider Electric
- Maximum Horse Power Rating : 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA
- Maximum Horse Power Rating : 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL
- Maximum Horse Power Rating : 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA
- Maximum Horse Power Rating : 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL
- Maximum Horse Power Rating : 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA
- Maximum Horse Power Rating : 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL
- Maximum Horse Power Rating : 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA
- Maximum Horse Power Rating : 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL
- Maximum Horse Power Rating : 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA
- Maximum Horse Power Rating : 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL
- Maximum Horse Power Rating : 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA
- Maximum Horse Power Rating : 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL
- maximum operating rate : 3600 cyc/h at 60 °C
- Mechanical Durability : 6000000 cycles
- Mechanical Robustness : Shocks contactor closed 15 Gn for 11 ms)
- Mechanical Robustness : Shocks contactor opened 10 Gn for 11 ms)
- Mechanical Robustness : Vibrations contactor closed 4 Gn, 5...300 Hz)
- Mechanical Robustness : Vibrations contactor opened 2 Gn, 5...300 Hz)
- minimum switching current : 5 mA for control circuit
- minimum switching voltage : 17 V for control circuit
- motor power kW : 15 kW at 220...230 V AC 50/60 Hz
- motor power kW : 22 kW at 380...400 V AC 50/60 Hz
- motor power kW : 25 kW at 415 V AC 50/60 Hz
- motor power kW : 30 kW at 440 V AC 50/60 Hz
- motor power kW : 30 kW at 500 V AC 50/60 Hz
- motor power kW : 33 kW at 660...690 V AC 50/60 Hz
- Mounting Support : Plate
- Mounting Support : Rail
- Net Weight : 3.09 lb(US) (1.4 kg)
- non-overlap time : 1.5 ms on de-energisation between NC and NO contacts
- non-overlap time : 1.5 ms on energisation between NC and NO contacts
- Number of Units in Package 2 : 18
- Number of Units in Package 3 : 144
- Operating Altitude : 9842.52 ft (3000 m) without derating
- Operating Time : 12...26 ms closing
- Operating Time : 4...19 ms opening
- Overvoltage Category : III
- Package 2 GTIN : 13389110426707
- Package 2 Height : 11.81 in (30.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 56.482 lb(US) (25.620 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 469.497 lb(US) (212.960 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- Permissible Ambient Air Temperature Around The Dev : 23…140 °F (-5…60 °C)
- Permissible Ambient Air Temperature Around The Dev : -40…158 °F (-40…70 °C) at Uc
- pole contact composition : 3 NO
- power dissipation per pole : 3.7 W AC-3
- power dissipation per pole : 3.7 W AC-3e
- power dissipation per pole : 9.6 W AC-1
- Product Certifications : BV
- Product Certifications : CCC
- Product Certifications : CSA
- Product Certifications : DNV
- Product Certifications : GL
- Product Certifications : GOST
- Product Certifications : LROS (pending)
- Product Certifications : RINA
- Product Certifications : UKCA
- Product Certifications : UL
- Product Or Component Type : Contactor
- protective cover : With
- PVC free : Yes
- Range : TeSys
- rated breaking capacity : 900 A at 440 V for power circuit conforming to IEC 60947
- REACh free of SVHC : Yes
- safety reliability level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- safety reliability level : B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Standards : CSA C22.2 No 14
- Standards : EN 60947-4-1
- Standards : EN 60947-5-1
- Standards : IEC 60947-4-1
- Standards : IEC 60947-5-1
- Standards : UL 508
- Sustainable packaging : Yes
- Take-back : No
- Tightening Torque : Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal flat Ø 6 mm
- Tightening Torque : Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal Philips No 2
- Tightening Torque : Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal pozidriv No 2
- Tightening Torque : Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 mm
- Tightening Torque : Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 8 mm
- Toxic heavy metal free : Yes
- Type Of Network : 3P
- Unit Type of Package 2 : S03
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39121529
- UNSPSC Classification v23 : 39121529
- utilisation category : AC-1
- utilisation category : AC-2
- utilisation category : AC-3
- utilisation category : AC-3e
- utilisation category : AC-4
- Volume of Package 2 : 36000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Warranty : 18 months
- Width : 2.2 in (55 mm)