Sensor, CO2, Duct, LCD, VOC
- [Us] rated supply voltage : 20...30 V DC
- [Us] rated supply voltage : 24 V AC
- Analogue Output Type : 0...10 V DC
- Analogue Output Type : 0...5 V DC
- Analogue Output Type : 4...20 mA
- Application : HVAC
- Application : Indoor air quality (IAQ)
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 264
- CO2 Measurement Accuracy : +/- 30 ppm + 3 % of reading
- CO2 Measurement Range : 0...2000 ppm
- CO2 Measurement Range : 0...5000 ppm
- CO2 Measurement Repeatability : +/- 20 ppm +/- 1 % of measured value
- Color : Duct Black and Green
- Communication Network Type : Wired
- Connections - Terminals : Screwless terminals
- Enclosure Material : Polycarbonate strong housing
- Final Result for Connectable : Connectable ready
- Final Result for Flywheel performance tracking : Connectable products
- Global Keywords : Air Quality
- Global Keywords : Analog
- Global Keywords : CO2
- Global Keywords : Duct
- Global Keywords : Plant Room
- Global Keywords : Sensor
- Global Keywords : VOC
- Global warming ; Total life cycle? : 264 kg CO2 eq.
- Indivisible Sale Qty : 1
- IP Degree of Protection : IP65
- Location : Indoor
- Manufacturer : Veris Industries
- Market Segment : Buildings
- Measurement Temperature : 32…122 °F (0…50 °C)
- Number of Units in Package 2 : 4
- Output Type : Analog
- Package 2 GTIN : 13606485849307
- Package 2 Height : 11.81 in (30 cm)
- Package 2 Length : 15.75 in (40 cm)
- Package 2 Weight : 4.4 lb(US) (2 kg)
- Package 2 width : 11.81 in (30 cm)
- Packaging made with recycled cardboard : No
- Packaging without single use plastic : No
- Product Name : Plant Room Air Quality Sensor
- Product Or Component Type : Sensor
- Range : SCD2 Series
- Relative Humidity : 0…95 % RH, non-condensing
- SCIP Number : 13db3b86-12c8-4e46-ac4a-00ab4bcc41a5
- Sensor Type : NDIR (non-dispersive infrared) CO2
- Sensor Type : Solid state Volatile Organic Compounds (VOC)
- Standards : EN 61000
- Standards : EN 61000-6-2
- Standards : EN 61000-6-3
- Standards : EN 61326-1
- Standards : FCC Part 15 class A
- Standards : ICES-003
- Standards : REACH
- Standards : RoHS
- Standards : UL 916
- Take-back : No
- Temperature Measurement Accuracy : +/- 0.2 °C
- Temperature Resolution : 0.1 °C
- Type Of Measurement : CO2
- Type Of Measurement : Volatile Organic Compounds (VOC)
- Unit Type of Package 2 : S03
- VOC Measurement Accuracy : +/- 15 %
- VOC Measurement Range : 0...100 % AQI
- Volume of Package 2 : 36000 cm3~~
No Reviews Yet
Write a Review