APC NetShelter Rack PDU Advanced, Metered, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 Outlet
- Acceptable Input Voltage : 200…240 V
- After sales category ASC : 01 - Replace by the same Commercial Reference : new (ie not refurbished)
- Brand : APC Brand
- Cable Length : 9.8 ft (3.0 m)
- Carbon footprint (kg CO2 eq, Total Life cycle) : 9379
- Channel status : Distribution
- Color : Black
- Communication Port Protocol : 10/100BASE-T
- Communication Port Protocol : 1000BASE-T
- Configurators/Selectors : Large data centers
- Configurators/Selectors : Medium data centers
- Configurators/Selectors : NetShelter
- Configurators/Selectors : PDU Selector
- CR severity code : 06 - Product as a spare
- CR shelf life : 0
- Depth : 2.95 in (7.5 cm)
- Final Result for Connectable : Connectable ready
- Final Result for Flywheel performance tracking : Connectable products
- For Service Catalog Item : Finished good
- Form name : PDU
- Global Keywords : APC rack PDU
- Global Keywords : Combination Outlet PDU
- Global Keywords : Rack pdu
- Global Keywords : Rack power distribution
- Global Keywords : Rackmount PDU
- Global warming ; Total life cycle? : 9 379 kg CO2 eq.
- Height : 58.66 in (149.0 cm)
- Input Connection Type : NEMA L6-30P
- input current limits : 30 A
- Input Frequency : 50/60 Hz
- IP Degree of Protection : IP44
- Lead time : Usually in Stock
- Line Rated Current : 24 A
- Load Capacity : 4992 VA
- Main Input Voltage : 208 V 1 phase
- Manufacturer : American Power Conversion Corp. (APC)
- Maximum Total Current Draw per Phase : 24 A
- Mounting Location : Side
- Mounting Mode : Rack-mounted
- mounting position : Vertical
- Mounting Preference : No preference
- Net Weight : 14.6 lb(US) (6.6 kg)
- number of power socket outlets : 20 C13/C15/C19/C21
- number of power socket outlets : 20C13/C15
- number of rack unit : 0U
- OEM : APC
- Operating Altitude : 0...10000 ft
- Order method : ERP to ERP
- Output Voltage : 208 V
- Packaging made with recycled cardboard : No
- Packaging without single use plastic : No
- PDU Type : Metered
- Preventive maintenance : 0
- Prod Type : PDU_PDU
- Product Certifications : BAA compliance
- Product Certifications : TAA compliance
- Product Or Component Type : PDU
- Protection Type : Circuit breaker
- REACh free of SVHC : Yes
- Relative Humidity : 5…95 %
- Return code : 03 - Return for Qualified Recycle (RQR)
- Spare Part Order Method direction : Consult local ERP Setup
- Spare used in spare kit : No
- Standards : CSA C22.2 No 62368-1
- Standards : FCC part 15 subpart B
- Standards : UL 62368-1
- Storage Altitude : 0…50000 ft (0…15240 m)
- Storage Relative Humidity : 5…95 %
- Take-back : No
- Temperature Ambient Operating Range : 23…140 °F (-5…60 °C)
- Temperature Shipping and Storage Range : -13…149 °F (-25…65 °C)
- Warranty : 3 years repair or replace
- Width : 2.20 in (5.6 cm)~~