Variable Speed Drive ATV630|Wall Mount|Supply Frequency: 50...60 Hz - 5...5 %|Us Rated Supply Voltage: 380...480 V - 15...10 %|226mm W x 6736mm H x 271mm D
- Brand : Schneider Electric
- By Schneider : Yes
- capacity of DC link : 2500.0 µF
- Carbon footprint (kg CO2 eq, Total Life cycle) : 30818
- Circular Eligibility : Refurbish list
- discrete and process manufacturing : Water and waste water Conveyor
- discrete and process manufacturing : Water and waste water Electro submersible pump (ESP)
- discrete and process manufacturing : Water and waste water Fan
- discrete and process manufacturing : Water and waste water Lobe compressor
- discrete and process manufacturing : Water and waste water Mixer
- discrete and process manufacturing : Water and waste water Other application
- discrete and process manufacturing : Water and waste water Positive displacement pump
- Global Keywords : Heavy duty
- Global Keywords : Low voltage speed drive
- Global Keywords : Normal duty
- Global Keywords : Schneider
- Global Keywords : Schneider electric
- Global Keywords : Se
- Global Keywords : Speed drive
- Global Keywords : UL type 1
- Global Keywords : Variable frequency drive
- Global Keywords : Variable speed drive
- Global Keywords : Vsd for asynchronous motor
- Global Keywords : Vsd for synchronous motor
- Global warming ; Total life cycle? : 30 818 kg CO2 eq.
- Height : 26.5 in (673 mm)
- input compatibility : DI5, DI6 discrete input level 1 PLC IEC 65A-68
- input compatibility : STOA, STOB discrete input level 1 PLC IEC 61131-2
- insulation resistance : > 1 MOhm 500 V DC for 1 minute to earth
- IP Degree of Protection : IP21
- IP Degree of Protection : IP21IEC 60529
- IP Degree of Protection : IP21IEC 61800-5-1
- isolation : Between power and control terminals
- line current : 48.3 A 480 V heavy duty)
- line current : 54.8 A 380 V heavy duty)
- line current : 57.3 A 480 V normal duty)
- line current : 66.2 A 380 V normal duty)
- linearity error : AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
- linearity error : AO1, AO2 +/- 0.2 % analog output
- Local Signalling : 1 LED (red) for presence of voltage
- Local Signalling : 3 LEDs (dual colour) for embedded communication status
- Local Signalling : 3 LEDs for local diagnostic
- Local Signalling : 4 LEDs (dual colour) for communication module status
- Manufacturer : Schneider Electric
- Marking : CE
- maximum acceleration under shock impact (during op : 150 m/s² at 11 ms
- maximum acceleration under shock load (during stor : 150 m/s² at 11 ms
- maximum acceleration under shock load (during tran : 150 m/s² at 11 ms
- maximum acceleration under vibrational stress (dur : 10 m/s² at 13...200 Hz
- maximum acceleration under vibratory load (during : 10 m/s² at 13...200 Hz
- maximum associated fuse rating : 125.0 A
- maximum deflection under vibratory load (during op : 1.5 mm at 2...13 Hz
- maximum deflection under vibratory load (during st : 1.5 mm at 2...13 Hz
- maximum deflection under vibratory load (during tr : 1.5 mm at 2...13 Hz
- Maximum Horse Power Rating : 40 hp heavy duty
- Maximum Horse Power Rating : 50 hp normal duty
- Maximum Input Current per phase : 66.2 A
- maximum output frequency : 500 kHz
- maximum output voltage : 480.0 V
- option card : Slot A communication module, Profinet
- option card : Slot A/slot B digital and analog I/O extension module
- option card : Slot A/slot B output relay extension module
- Overvoltage Category : III
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : No
- permissible temporary current boost : 1.1 x In 60 s normal duty)
- permissible temporary current boost : 1.5 x In 60 s heavy duty)
- permitted relative humidity (during operation) : Class 3K5 according to EN 60721-3
- permitted relative humidity (during storage) : Class 1K5 according to EN 60721-3
- permitted relative humidity (during transport) : Class 2K5 according to EN 60721-3
- Phase : 3 phase
- Physical Interface : 2-wire RS 485
- Physical Interface : Ethernet
- Pollution Degree : 2
- Pollution Degree : 2 IEC 61800-5-1
- power dissipation in W : Forced convection 796 W 380 V 4 kHz
- power dissipation in W : Natural convection 106 W 380 V 4 kHz
- power loss per device current dependent : 1030.0 W
- power loss static current independent : 31.0 W
- power range : 30-50 kW 380-440 V 3 phase
- power range : 30-50 kW 480-500 V 3 phase
- Product Certifications : ATEX INERIS
- Product Certifications : ATEX zone 2/22
- Product Certifications : CSA
- Product Certifications : DNV-GL
- Product Certifications : TÜV
- Product Certifications : UL
- Product contributes to saved and avoided emissions : Yes
- Product Destination : Asynchronous motors
- Product Destination : Synchronous motors
- Product Or Component Type : Variable speed drive
- Product Specific Application : Process and utilities
- prospective line Isc : 50 kA
- Protection Type : Break on the control circuit drive
- Protection Type : Line supply overvoltage drive
- Protection Type : Line supply phase loss drive
- Protection Type : Line supply undervoltage drive
- Protection Type : Motor phase break drive
- Protection Type : Motor phase break motor
- Protection Type : Overcurrent between output phases and earth drive
- Protection Type : Overheating drive
- Protection Type : Overload of output voltage drive
- Protection Type : Overspeed drive
- Protection Type : Overvoltages on the DC bus drive
- Protection Type : Safe torque off drive
- Protection Type : Safe torque off motor
- Protection Type : Short-circuit protection drive
- Protection Type : Thermal protection drive
- Protection Type : Thermal protection motor
- Quantity Per Set : 1
- refresh time : Relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Regulation Loop : Adjustable PID regulator
- Relative Humidity : 5-95 % without condensation IEC 60068-2-3
- relative symmetric mains voltage tolerance : 10 %
- relative symmetric network frequency tolerance : 5 %
- relay output number : 3
- relay output type : Configurable relay logic R1 fault relay NO/NC 100000 cycles
- relay output type : Configurable relay logic R2 sequence relay NO 100000 cycles
- relay output type : Configurable relay logic R3 sequence relay NO 100000 cycles
- Safety Function : STO (safe torque off) SIL 3
- sampling duration : 10 ms +/- 1 ms AO1) - analog output
- sampling duration : 2 ms +/- 0.5 ms DI1...DI4) - discrete input
- sampling duration : 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
- sampling duration : 5 ms +/- 1 ms DI5, DI6) - discrete input
- SCIP Number : 8ac43dc1-9e7e-4e1a-a3ee-665587b07cd7
- shock resistance : 15 gn 11 ms IEC 60068-2-27
- specific application : Utility
- speed drive output frequency : 0.1-500 Hz
- Standards : IEC 13849-1
- Standards : IEC 60721-3
- Standards : IEC 61000-3-12
- Standards : IEC 61508
- Standards : UL 508C
- Standards : EN/IEC 61800-3 environment 2 category C3
- Standards : Environment 1 category C2 IEC 61800-3
- Standards : Environment 2 category C3 IEC 61800-3
- Standards : IEC 61800-3
- Standards : IEC 61800-3 environment 1 category C2
- Standards : IEC 61800-5-1
- Supply Frequency : 50...60 Hz - 5...5 %
- supporting protocol for ASI : No
- supporting protocol for AS-Interface Safety at Wor : No
- supporting protocol for BACnet : No
- supporting protocol for CAN : Yes
- supporting protocol for Data-Highway : No
- supporting protocol for DeviceNet : No
- supporting protocol for DeviceNet Safety : No
- supporting protocol for EtherNet/IP : Yes
- supporting protocol for Foundation Fieldbus : No
- supporting protocol for INTERBUS : No
- supporting protocol for INTERBUS-Safety : No
- supporting protocol for KNX : No
- supporting protocol for LON : No
- supporting protocol for MODBUS : Yes
- supporting protocol for other bus systems : No
- supporting protocol for PROFIBUS : Yes
- supporting protocol for PROFINET CBA : Yes
- supporting protocol for PROFINET IO : Yes
- supporting protocol for PROFIsafe : No
- supporting protocol for SafetyBUS P : No
- supporting protocol for SERCOS : No
- supporting protocol for SUCONET : No
- supporting protocol for TCP/IP : Yes
- Switching Frequency : 2...12 kHz adjustable
- Switching Frequency : 4...12 kHz with derating factor
- synchronous motor control profile : Permanent magnet motor
- synchronous motor control profile : Synchronous reluctance motor
- Take-back : No
- Temperature Ambient Operating Range : 5-140 °F (-15-60 °C)
- Temperature Shipping and Storage Range : -40-158 °F (-40-70 °C)
- transmission frame : RTU
- Transmission Rate : 10, 100 Mbits
- Transmission Rate : 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
- type of cooling : Forced convection
- type of polarization : No impedance
- UNSPSC Classification v19 : 39122001
- UNSPSC Classification v23 : 39122001
- variant : Standard version
- vibration resistance : 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
- vibration resistance : 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
- volume of cooling air : 63402.4 Gal/hr(US) (240 m3/h)
- Width : 8.9 in (226 mm)
- with safety function Safe brake management (SBC/SB : No
- with safety function Safe Direction (SDI) : No
- with safety function Safe Operating Stop (SOS) : No
- with safety function Safe Position (SP) : No
- with safety function Safe programmable logic : No
- with safety function Safe Speed Monitor (SSM) : No
- with safety function Safe Stop 1 (SS1) : No
- with safety function Safe torque off (STO) : Yes
- with safety function Safely Limited Position (SLP) : No
- with safety function Safely Limited Speed (SLS) : No
- with sft fct Safe Stop 2 (SS2) : No