Variable Speed Drive ATV630|Wall Mount|Supply Frequency: 50...60 Hz - 5...5 %|Us Rated Supply Voltage: 200...240 V - 15...10 %|173mm W x 405mm H x 231mm D
- Brand : Schneider Electric
- By Schneider : Yes
- capacity of DC link : 3280.0 µF
- Carbon footprint (kg CO2 eq, Total Life cycle) : 7854
- Communication Port Protocol : Ethernet
- Communication Port Protocol : Modbus serial
- Communication Port Protocol : Modbus TCP
- computer port : Yes
- Connector Type : RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
- Connector Type : RJ45 on the remote graphic terminal)Modbus serial
- continuous output current : 18.7 A 4 kHz heavy duty
- continuous output current : 25.4 A 4 kHz normal duty
- data format : 8 bits, configurable odd, even or no parity
- degree of protection : UL type 1 UL 508C
- Global Keywords : ATV600
- Global Keywords : Heavy duty
- Global Keywords : Ip21 speed drive
- Global Keywords : Low voltage speed drive
- Global Keywords : Normal duty
- Global Keywords : Schneider
- Global Keywords : Schneider electric
- Global Keywords : Se
- Global Keywords : Speed drive
- Global Keywords : UL type 1
- Global Keywords : Variable frequency drive
- Global Keywords : Variable speed drive
- Global Keywords : Vsd for asynchronous motor
- Global Keywords : Vsd for synchronous motor
- Global warming ; Total life cycle? : 7 854 kg CO2 eq.
- Height : 16.1 in (409 mm)
- housing material : Plastic
- input compatibility : DI1...DI6 discrete input level 1 PLC IEC 61131-2
- Maximum Switching Current : Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
- Maximum Switching Current : Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
- maximum transient current : 27.9 A 60 s normal duty)
- maximum transient current : 28.1 A 60 s heavy duty)
- method of access : Slave Modbus TCP
- minimum switching current : Relay output R1, R2, R3 5 mA 24 V DC
- motor power kW : 4 kW heavy duty)
- motor power kW : 5.5 kW normal duty)
- motor slip compensation : Adjustable
- motor slip compensation : Automatic whatever the load
- motor slip compensation : Can be suppressed
- motor slip compensation : Not available in permanent magnet motor law
- motor starter type : Variable speed drive
- Mounting Mode : Wall mount
- NEMA Protection Rating : NEMA 1
- Net Weight : 17.0 lb(US) (7.7 kg)
- Network Frequency : 50-60 Hz
- noise level : 56 dB
- noise level : 56 dB 86/188/EEC
- nominal output current : 25.4 A
- Nominal Output Power : 5.5 kW
- nominal switching frequency : 4 kHz
- number of addresses : 1-247 Modbus serial
- number of HW interfaces industrial Ethernet : 1
- number of HW interfaces other : 0
- number of HW interfaces parallel : 0
- number of HW interfaces PROFINET : 0
- number of HW interfaces serial RS232 : 0
- number of HW interfaces serial RS422 : 0
- number of HW interfaces serial RS485 : 1
- number of HW interfaces serial TTY : 0
- number of HW interfaces USB : 0
- number of input phases : 3
- number of inputs, bidirectional, not potential-fre : 0
- number of inputs, potential-free : 0
- number of output phases : 3
- Number of Units in Package 2 : 3
- Operating Altitude : 1000...4800 m with current derating 1 % per 100 m
- operating element present : Yes
- operating position : Vertical +/- 10 degree
- optical interface present : No
- option card : communication module, Ethernet Powerlink
- option card : Communication module, BACnet MS/TP
- option card : Slot A communication module, CANopen daisy chain RJ45
- option card : Slot A communication module, CANopen screw terminals
- option card : Slot A communication module, CANopen SUB-D 9
- option card : Slot A communication module, DeviceNet
- option card : Slot A communication module, Modbus TCP/EtherNet/IP
- option card : Slot A communication module, Profibus DP V1
- option card : Slot A communication module, Profinet
- option card : Slot A/slot B digital and analog I/O extension module
- option card : Slot A/slot B output relay extension module
- Overvoltage Category : III
- Package 2 GTIN : 73606485410882
- Package 2 Height : 29.53 in (75.000 cm)
- Package 2 Length : 31.50 in (80.000 cm)
- Package 2 Weight : 96.141 lb(US) (43.609 kg)
- Package 2 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- permissible temporary current boost : 1.1 x In 60 s normal duty)
- permissible temporary current boost : 1.5 x In 60 s heavy duty)
- permitted relative humidity (during operation) : Class 3K5 according to EN 60721-3
- permitted relative humidity (during storage) : Class 1K5 according to EN 60721-3
- permitted relative humidity (during transport) : Class 2K5 according to EN 60721-3
- Phase : 3 phase
- Physical Interface : 2-wire RS 485
- Physical Interface : Ethernet
- Pollution Degree : 2
- Pollution Degree : 2 IEC 61800-5-1
- power dissipation in W : Forced convection 179 W 200 V 4 kHz
- power dissipation in W : Natural convection 47 W 200 V 4 kHz
- power loss per device current dependent : 255.0 W
- power loss static current independent : 16.0 W
- relay output type : Configurable relay logic R1 fault relay NO/NC 100000 cycles
- relay output type : Configurable relay logic R2 sequence relay NO 100000 cycles
- relay output type : Configurable relay logic R3 sequence relay NO 100000 cycles
- Safety Function : STO (safe torque off) SIL 3
- sampling duration : 10 ms +/- 1 ms AO1) - analog output
- sampling duration : 2 ms +/- 0.5 ms DI1...DI4) - discrete input
- sampling duration : 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
- sampling duration : 5 ms +/- 1 ms DI5, DI6) - discrete input
- SCIP Number : 1c05d307-8212-426b-a56b-addc96693166
- shock resistance : 15 gn 11 ms IEC 60068-2-27
- specific application : Utility
- speed drive output frequency : 0.1-500 Hz
- Standards : IEC 13849-1
- Standards : IEC 60721-3
- Standards : IEC 61000-3-12
- Standards : IEC 61508
- Standards : UL 508C
- Standards : EN/IEC 61800-3 environment 2 category C3
- Standards : Environment 1 category C2 IEC 61800-3
- Standards : Environment 2 category C3 IEC 61800-3
- Standards : IEC 61800-3
- Standards : IEC 61800-3 environment 1 category C2
- Standards : IEC 61800-5-1
- Supply Frequency : 50...60 Hz - 5...5 %
- supporting protocol for ASI : No
- supporting protocol for AS-Interface Safety at Wor : No
- supporting protocol for BACnet : No
- supporting protocol for CAN : Yes
- supporting protocol for Data-Highway : No
- supporting protocol for DeviceNet : No
- supporting protocol for DeviceNet Safety : No
- supporting protocol for EtherNet/IP : Yes
- supporting protocol for Foundation Fieldbus : No
- supporting protocol for INTERBUS : No
- supporting protocol for INTERBUS-Safety : No
- supporting protocol for KNX : No
- supporting protocol for LON : No
- supporting protocol for MODBUS : Yes
- supporting protocol for other bus systems : No
- supporting protocol for PROFIBUS : Yes
- supporting protocol for PROFINET CBA : Yes
- supporting protocol for PROFINET IO : Yes
- supporting protocol for PROFIsafe : No
- supporting protocol for SafetyBUS P : No
- supporting protocol for SERCOS : No
- supporting protocol for SUCONET : No
- supporting protocol for TCP/IP : Yes
- Switching Frequency : 2...12 kHz adjustable
- Switching Frequency : 4...12 kHz with derating factor
- synchronous motor control profile : Permanent magnet motor
- synchronous motor control profile : Synchronous reluctance motor
- Take-back : No
- Temperature Ambient Operating Range : 5-140 °F (-15-60 °C)
- Temperature Shipping and Storage Range : -40-158 °F (-40-70 °C)
- transmission frame : RTU
- Transmission Rate : 10, 100 Mbits
- Transmission Rate : 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
- type of cooling : Forced convection
- type of polarization : No impedance
- Unit Type of Package 2 : P06
- UNSPSC Classification v19 : 39122001
- UNSPSC Classification v23 : 39122001
- variant : Standard version
- vibration resistance : 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
- vibration resistance : 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
- volume of cooling air : 27210.2 Gal/hr(US) (103 m3/h)
- Volume of Package 2 : 360000.000 cm3
- Width : 6.7 in (171 mm)
- with safety function Safe brake management (SBC/SB : No
- with safety function Safe Direction (SDI) : No
- with safety function Safe Operating Stop (SOS) : No
- with safety function Safe Position (SP) : No
- with safety function Safe programmable logic : No
- with safety function Safe Speed Monitor (SSM) : No
- with safety function Safe Stop 1 (SS1) : No
- with safety function Safe torque off (STO) : Yes
- with safety function Safely Limited Position (SLP) : No
- with safety function Safely Limited Speed (SLS) : No
- with sft fct Safe Stop 2 (SS2) : No