TeSys D Contactor |Number of Poles: 3-Poles|Pole Contact Composition: 3 NO|Rated Operational Current: 40A|Control Circuit Voltage: 110V AC 50/60 Hz|Non-Reversing
[Ie] rated operational current :
40 A (at~~
[Ie] rated operational current :
40 A (at
[Ie] rated operational current :
60 A (at
[Ith] conventional free air thermal current :
10 A (at 140 °F (60 °C)) for control circuit
[Ith] conventional free air thermal current :
60 A (at 140 °F (60 °C)) for power circuit
[Uc] control circuit voltage :
110 V AC 50/60 Hz
[Ue] rated operational voltage :
Power circuit
[Ui] rated insulation voltage :
Control circuit 600 V CSA
[Ui] rated insulation voltage :
Control circuit 600 V UL
[Ui] rated insulation voltage :
Control circuit 690 V IEC 60947-1
[Ui] rated insulation voltage :
Power circuit 600 V CSA
[Ui] rated insulation voltage :
Power circuit 600 V UL
[Ui] rated insulation voltage :
Power circuit 690 V IEC 60947-1
[Uimp] rated impulse withstand voltage :
8 kV IEC 60947
Associated Fuse Rating :
80 A gG at
auxiliary contact composition :
1 NO + 1 NC
auxiliary contacts type :
Mirror contact 1 NC IEC 60947-4-1
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
56
climatic withstand :
IACS E10 exposure to damp heat
contactor application :
Motor control
contactor application :
Resistive load
control circuit type :
AC 50/60 Hz
Depth :
4.7 in (119 mm)
Device Short Name :
LC1D
Final Result for Flywheel performance tracking :
Non Flywheel
Flame Retardance :
V1 conforming to UL 94
Global Keywords :
AC coil
Global Keywords :
AC control
Global Keywords :
CTR
Global warming ; Total life cycle? :
56 kg CO2 eq.
Height :
5 in (127 mm)
Hold-In Power Consumption In Va :
13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-In Power Consumption In Va :
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
insulation resistance :
> 10 MOhm for control circuit
IP Degree of Protection :
IP2x IEC 60529
IP Degree of Protection :
IP2x VDE 0106
Manufacturer :
Schneider Electric
Maximum Horse Power Rating :
10 hp at 200/208 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
10 hp at 230/240 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
3 hp at 115 V AC 60 Hz for 1 phase motors
Maximum Horse Power Rating :
30 hp at 460/480 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
30 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
5 hp at 230/240 V AC 60 Hz for 1 phase motors
maximum operating rate :
3600 cyc/h at 60 °C
Mechanical Durability :
6000000 cycles
minimum switching current :
5 mA for control circuit
minimum switching voltage :
17 V for control circuit
Mounting Support :
Plate
Mounting Support :
Rail
Net Weight :
3.09 lb(US) (1.4 kg)
Number of Units in Package 2 :
5
Operating Altitude :
0...9842.52 ft (0...3000 m)
Operating Time :
12...26 ms closing
Operating Time :
4...19 ms opening
Overvoltage Category :
III
Package 2 GTIN :
43389110416914
Package 2 Height :
5.91 in (15 cm)
Package 2 Length :
15.75 in (40 cm)
Package 2 Weight :
16.526 lb(US) (7.496 kg)
Package 2 width :
11.81 in (30 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
No
pole contact composition :
3 NO
power dissipation per pole :
2.4 W AC-3
power dissipation per pole :
2.4 W AC-3e
power dissipation per pole :
5.4 W AC-1
Product Certifications :
BV
Product Certifications :
CB
Product Certifications :
CCC
Product Certifications :
CSA
Product Certifications :
DNV
Product Certifications :
GL
Product Certifications :
GOST
Product Certifications :
LROS (Lloyds register of shipping)
Product Certifications :
RINA
Product Certifications :
UL
Product Or Component Type :
Contactor
protective cover :
With
PVC free :
Yes
Range :
TeSys
REACh free of SVHC :
Yes
Standards :
CSA C22.2 No 14
Standards :
EN 60947-4-1
Standards :
EN 60947-5-1
Standards :
IEC 60947-4-1
Standards :
IEC 60947-5-1
Standards :
UL 508
Take-back :
No
Toxic heavy metal free :
Yes
Type Of Network :
3P
Unit Type of Package 2 :
S02
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
utilisation category :
AC-1
utilisation category :
AC-2
utilisation category :
AC-3
utilisation category :
AC-3e
utilisation category :
AC-4
Volume of Package 2 :
18000 cm3
Warranty :
18 months
Width :
3.0 in (75 mm)