Liquid level control relay RM35-L - 24..240 V AC/DC
- [Uc] control circuit voltage : 24...240 V~~
- [Ui] rated insulation voltage : 250 V IEC 60664-1
- [Uimp] rated impulse withstand voltage : 4 kV IEC 60255-5
- [Uimp] rated impulse withstand voltage : 4 kV IEC 60664-1
- [Uimp] rated impulse withstand voltage : 4 kV IEC 61000-4-5
- [Us] rated supply voltage : 24...240 V AC/DC 50/60 Hz, non self-powered
- Ambient Air Temperature For Operation : -4…122 °F (-20…50 °C)
- Brand : Schneider Electric
- By Schneider : Yes
- cable capacitance : 1 nF HS (High Sensitivity) probe cable
- cable capacitance : 2.2 nF St (Standard Sensitivity) probe cable
- cable capacitance : 4.7 nF LS (Low Sensitivity)
- Carbon footprint (kg CO2 eq, Total Life cycle) : 43
- Circular Eligibility : Repack list
- Connections - Terminals : Screw connectors
- Connections - Terminals : Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
- Connections - Terminals : Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
- Connections - Terminals : Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- Connections - Terminals : Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
- Contacts Type And Composition : 2 C/O
- control circuit voltage limits : - 15 % + 10 % Un
- dielectric test voltage : 2 kV AC 50 Hz, 1 min IEC 60255-5
- dielectric test voltage : 2 kV AC 50 Hz, 1 min IEC 60664-1
- Electrical Durability : 100000 cycles
- Electromagnetic Compatibility : Emission standard for industrial environments conforming to IEC 61000-6-4
- Electromagnetic Compatibility : Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
- Electromagnetic Compatibility : Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
- Final Result for Flywheel performance tracking : Non Flywheel
- functionality : Resistive probe detection
- Global Keywords : 2 C/O Output Contacts
- Global Keywords : 35mm
- Global Keywords : 3-phase liquid level monitoring relay
- Global Keywords : DIN rail mounted
- Global Keywords : DPDT
- Global Keywords : Harmony Control
- Global Keywords : Liquid level detection by resistive probes
- Global Keywords : RM35
- Global Keywords : Schneider electric
- Global warming ; Total life cycle? : 43 kg CO2 eq.
- housing material : Self-extinguishing plastic
- immunity to microbreaks : 100 ms DC
- immunity to microbreaks : 90 ms AC
- insulation resistance : > 1 MOhm 500 V DC between supply and measurement IEC 60255-5
- insulation resistance : > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
- insulation resistance : > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
- insulation resistance : > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
- insulation resistance : > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
- insulation resistance : > 500 MOhm 500 V DC between supply and relay output IEC 60664-1
- IP Degree of Protection : IP20 IEC 60529 terminals)
- IP Degree of Protection : IP30 IEC 60529 casing)
- Line Rated Current : 5 A
- Local Signalling : LED (green) for power ON
- Local Signalling : LED (yellow) for relay ON
- Local Signalling : LED (yellow) for timer ON
- Manufacturer : Schneider Electric
- Marking : CE : 73/23/EEC
- Marking : CE : EMC 89/336/EEC
- Maximum Power Consumption In Va : 5 VA AC
- Maximum Power Consumption In W : 1.5 W DC
- maximum supply current for sensors : 1 mA
- Maximum Switching Current : 5 A AC/DC
- maximum switching voltage : 250 V AC/DC
- Measurement Accuracy : +/- 10 % of the full scale value
- Measurement Accuracy : +/- 20 % for the HS range
- measurement error : 0.5 %/°C with temperature variation
- Measurement Range : 0.25...1000 kOhm
- Measurement Range : 250 Ohm...1 MOhm
- Mechanical Durability : 30000000 cycles
- minimum switching current : 10 mA 5 V DC
- Mounting Support : 35 mm symmetrical DIN rail conforming to IEC 60715
- nominal output current : 5 A
- Number of Units in Package 2 : 48
- Number of Units in Package 3 : 384
- operating position : Any position without derating
- output contacts : 2 C/O
- Override : Without test button
- Overvoltage Category : III conforming to IEC 60664-1
- Package 2 GTIN : 43389119405230
- Package 2 Height : 11.81 in (30.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 15.774 lb(US) (7.155 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 144.756 lb(US) (65.660 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : Yes
- Pollution Degree : 3 IEC 60664-1
- Product Certifications : CSA
- Product Certifications : C-tick
- Product Certifications : GL
- Product Certifications : GOST
- Product Certifications : UL
- Product Or Component Type : Level control relay
- Relative Humidity : 95 % 131 °F (55 °C) IEC 60068-2-30
- relay monitored parameters : Detection by resistive probes
- relay name : RM35L
- Relay Type : Level control relay
- Repeat Accuracy : +/- 2 % time delay
- reset time : 1750 ms
- run-up delay at power-up : 0.6 s
- safety reliability data : B10d = 170000
- safety reliability data : MTTFd = 182.6 years
- sensitivity adjustment : 5…100 %
- sensitivity scale : 0.25...5 kOhm LS (Low Sensitivity)
- sensitivity scale : 5...100 kOhm St (Standard Sensitivity)
- sensitivity scale : 50...1000 kOhm HS (High Sensitivity)
- Standards : IEC 60255-6
- supply voltage limits : 20.4…264 V AC/DC
- Sustainable packaging : Yes
- switching capacity in VA : 1250 VA
- Take-back : No
- Temperature Shipping and Storage Range : -40…158 °F (-40…70 °C)
- Tightening Torque : 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
- time delay type : Adjustable 0.1...5 s, +/- 10 % Tt- time delay upon fault
- Unit Type of Package 2 : S03
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 39122331
- UNSPSC Classification v23 : 39122331
- utilisation category : AC-12 IEC 60947-5-1
- utilisation category : AC-13 IEC 60947-5-1
- utilisation category : AC-14 IEC 60947-5-1
- utilisation category : AC-15 IEC 60947-5-1
- utilisation category : DC-12 IEC 60947-5-1
- utilisation category : DC-13 IEC 60947-5-1
- Volume of Package 2 : 36000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Warranty : 18 months
- Width : 1.4 in (35 mm)