zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

AP8870

$1,642.67
(No reviews yet) Write a Review
SKU:
AP8870
Adding to cart… The item has been added
Rack PDU 2G, Metered, ZeroU, 30A, 00-120/200-240V, (16) 5-20R (12) C13 (2) C19
Brand :
APC Brand
Cable Length :
9.84 ft (3.00 m)
Carbon footprint (kg CO2 eq, Total Life cycle) :
39891
Channel status :
Distribution
Color :
Black
Configurators/Selectors :
Large data centers
Configurators/Selectors :
Medium data centers
Configurators/Selectors :
NetShelter
Configurators/Selectors :
PDU Selector
CR severity code :
06 - Product as a spare
CR shelf life :
12
Final Result for Connectable :
Connectable ready
Final Result for Flywheel performance tracking :
Connectable products
For Service Catalog Item :
Finished good
Form name :
PDU
Global warming ; Total life cycle? :
39 891 kg CO2 eq.
Halogen content performance :
Product contains halogen above thresholds
Input Connection Type :
NEMA L14-30P
input current limits :
30 A
Input Frequency :
50/60 Hz
Lead free :
Yes
Lead time :
Usually in Stock
Line Rated Current :
24 A
Load Capacity :
4992 VA
Main Input Voltage :
120 V
Main Input Voltage :
208 V
Manufacturer :
Schneider Electric
Maximum Total Current Draw per Phase :
24 A
Mounting Location :
Side
Mounting Mode :
Rack-mounted
mounting position :
Vertical
Mounting Preference :
No preference
Net Weight :
14.07 lb(US) (6.38 kg)
Number Of Cables :
1
number of power socket outlets :
12 IEC 60320 C13
number of power socket outlets :
16 NEMA 5-20R
number of power socket outlets :
2 IEC 60320 C19
number of rack unit :
0U
OEM :
APC
Operating Altitude :
0...10000 ft
Optimized Energy Efficiency :
Energy efficient product
Order method :
ERP to ERP
Other Output Voltages :
240 V
Output Voltage :
120 V
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
No
PDU Type :
Metered
Preventive maintenance :
0
Prod Type :
PDU_PDU
Product Certifications :
CUL Listed
Product Certifications :
UL Listed
Product Or Component Type :
PDU
Protection Type :
Circuit breaker
Provided Equipment :
Installation guide
Provided Equipment :
Rack Mounting brackets
Provided Equipment :
Safety guide
Provided Equipment :
Serial configuration cable
REACh free of SVHC :
Yes
Relative Humidity :
5…95 %
Removable battery :
Yes
Spare Part Order Method direction :
Consult local ERP Setup
Spare used in spare kit :
No
Standards :
FCC Part 15 class A
Standards :
ICES-003
Standards :
UL 60950-1
Storage Relative Humidity :
5…95 %
Take-back :
Yes
Temperature Ambient Operating Range :
23…140 °F (-5…60 °C)
Temperature Shipping and Storage Range :
-13…149 °F (-25…65 °C)
UNSPSC Classification v19 :
39121017
UNSPSC Classification v23 :
39121017
UPS size :
S

No Reviews Yet

Write a Review