zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

LAD4RCU

$44.47
(No reviews yet) Write a Review
SKU:
LAD4RCU
Adding to cart… The item has been added
[Uc] control circuit voltage :
110...250 V AC~~
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
1
Device Short Name :
LAD4
Final Result for Flywheel performance tracking :
Non Flywheel
Global Keywords :
Coil protection
Global Keywords :
Contactor accessory
Global Keywords :
LAD4
Global Keywords :
LAD4RC
Global Keywords :
Peak limiting
Global Keywords :
RC circuit
Global Keywords :
RC protection
Global Keywords :
Suppressor module
Global Keywords :
Surge protection
Global Keywords :
TeSys D
Global Keywords :
Transient suppressor
Global Keywords :
Transient voltage
Global warming ; Total life cycle? :
1 kg CO2 eq.
IP Degree of Protection :
IP2xIEC 60529
Manufacturer :
Schneider Electric
maximum peak voltage :
3 Uc
Mounting Location :
Side
Mounting Mode :
By clips
Number of Units in Package 2 :
70
Number of Units in Package 3 :
2240
Package 2 GTIN :
43389110385456
Package 2 Height :
5.91 in (15.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
2.661 lb(US) (1.207 kg)
Package 2 width :
5.91 in (15.000 cm)
Package 3 Height :
29.53 in (75.000 cm)
Package 3 Length :
31.50 in (80.000 cm)
Package 3 Weight :
107.010 lb(US) (48.539 kg)
Package 3 width :
23.62 in (60.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
No
Product Certifications :
CSA
Product Certifications :
UL
Product Compatibility :
CAD32, CAD50
Product Compatibility :
3P LC1D09...D38
Product Compatibility :
4P LC1D098...D258
Product Compatibility :
4P LC1DT20...DT40
Product Or Component Type :
Suppressor module
Range :
TeSys
REACh free of SVHC :
Yes
Standards :
EN 60947-5-1
Standards :
GB/T 14048.5
Standards :
IEC 60947-5-1
Standards :
UL 60947-5-1
suppressor technology :
RC circuit
Take-back :
No
Temperature Ambient Operating Range :
-13…131 °F (-25…55 °C)
Temperature Shipping and Storage Range :
-40…176 °F (-40…80 °C)
Toxic heavy metal free :
Yes
Unit Type of Package 2 :
S01
Unit Type of Package 3 :
P06
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
Volume of Package 2 :
9000.000 cm3
Volume of Package 3 :
360000.000 cm3
Warranty :
18 months

No Reviews Yet

Write a Review