zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

M9R84491

$1,027.80
(No reviews yet) Write a Review
SKU:
M9R84491
Adding to cart… The item has been added
Multi9 - GFP - RCCB - 4P - 100A - class A SI - 480Y/277 V - 260 mA instantaneou
[Ue] rated operational voltage :
415 V AC 50 Hz
[Ue] rated operational voltage :
480Y/277 V AC 60 Hz
[Ui] rated insulation voltage :
440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage :
6 kVEN/IEC 61008-1
9 mm pitches :
8
Ambient Air Temperature For Operation :
-13…140 °F (-25…60 °C)
Application :
Distribution
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
5
Color :
Gray
connection pitch :
0.7 in (18 mm) between phases
contact position indicator :
Yes
Depth :
2.4 in (60 mm)
Device Short Name :
GFP
earth-leakage protection class :
Type A-SI (Super Immunised)
earth-leakage protection time delay :
Instantaneous
earth-leakage sensitivity :
260 mA UL 1053
earth-leakage sensitivity :
300 mA EN/IEC 61008-1
Electromagnetic Compatibility :
8/20 µs impulse withstand, 3000 A EN/IEC 61008-1
Final Result for Connectable :
Connectable with upgrade
Final Result for Flywheel performance tracking :
Connectable products
Global Keywords :
Earth leakage
Global Keywords :
Earth leakage protection
Global Keywords :
Electric shock
Global Keywords :
Fault tripping
Global Keywords :
Low voltage rccb
Global Keywords :
Protection of persons
Global Keywords :
Rccb
Global Keywords :
Sensitivity
Global Keywords :
Trip
Global Keywords :
Tripping curve
Global Keywords :
Visisafe
Global Keywords :
Visitrip
Global warming ; Total life cycle? :
5 kg CO2 eq.
Halogen content performance :
Product contains halogen above thresholds
Height :
3.2 in (81 mm)
IP Degree of Protection :
IP20 conforming to IEC 60529
Local Signalling :
ON, OFF, fault trip
locking options description :
Padlocking in OFF position
Manufacturer :
Square D
Mechanical Durability :
20000 cycles
Mounting Mode :
Clip-on
Mounting Support :
DIN rail
Net Weight :
0.99 lb(US) (0.45 kg)
Network Frequency :
50/60 Hz
Network Type :
AC
neutral position :
Left
Number of Units in Package 2 :
27
Override :
Toggle
Package 2 GTIN :
43606481198578
Package 2 Height :
11.81 in (30.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
21.253 lb(US) (9.640 kg)
Package 2 width :
11.81 in (30.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
Yes
Pollution Degree :
3
Power losses per pole :
18 W
Product Certifications :
IEC
Product Certifications :
UL
Product Name :
Multi9 GFP
Product Or Component Type :
Residual current circuit breaker (RCCB)
PVC free :
No
Range :
Multi9
rated breaking and making capacity :
Idm 1500 A EN/IEC 61008-1
rated conditional short-circuit current :
Inc 10 kA 100 A gG
Relative Humidity :
95 % 131 °F (55 °C)
residual current tripping technology :
Voltage independent
Standards :
EN/IEC 61008-1
Standards :
UL 1053
Sustainable packaging :
Yes
Take-back :
No
Temperature Shipping and Storage Range :
-40…158 °F (-40…70 °C)
Total power losses :
54 W
tropicalisation :
2 IEC 60068-1
Type Of Network :
4P
Unit Type of Package 2 :
S03
UNSPSC Classification v19 :
39121633
UNSPSC Classification v23 :
39121633
utilisation category :
AC-23A EN/IEC 61008-1
Volume of Package 2 :
36000.000 cm3
Width :
2.8 in (72 mm)

No Reviews Yet

Write a Review