Safety module, Harmony Safety Automation, Cat.4, features 2*XPSUAF + enabling movement, 24v AC/DC, screw
- [Ie] rated operational current : 1 A AC-15 for normally closed relay contact
- [Ie] rated operational current : 1 A DC-13 for normally closed relay contact
- [Ie] rated operational current : 3 A AC-1 for normally closed relay contact
- [Ie] rated operational current : 3 A AC-15 for normally open relay contact
- [Ie] rated operational current : 3 A DC-1 for normally closed relay contact
- [Ie] rated operational current : 3 A DC-13 for normally open relay contact
- [Ie] rated operational current : 5 A AC-1 for normally open relay contact
- [Ie] rated operational current : 5 A DC-1 for normally open relay contact
- [Ith] conventional free air thermal current : 8 A
- [Ui] rated insulation voltage : 250 V 2)IEC 60947-1
- [Uimp] rated impulse withstand voltage : 4 kV II IEC 60947-1
- [Us] rated supply voltage : 24 V AC - 15...10 %
- [Us] rated supply voltage : 24 V DC - 20...20 %
- Associated Fuse Rating : 10 A gG NO relay output circuit IEC 60947-1
- auxiliary contact composition : 2 NO
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 70
- Connections - Terminals : Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
- Connections - Terminals : Removable screw terminal block, 0.2...2.5 mm² solid or flexible
- Connections - Terminals : Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
- Connections - Terminals : Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
- Connections - Terminals : Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
- Depth : 4.7 in (120 mm)
- electrical circuit type : Antivalent pair
- electrical circuit type : NC pair
- electrical circuit type : OSSD pair
- electrical circuit type : PNP pair
- Final Result for Flywheel performance tracking : Edge control
- function of module : Emergency stop button with 2 NC contacts
- function of module : Enabling switch monitoring
- function of module : Guard monitoring with 1 or 2 limit switches
- function of module : Light curtain monitoring
- function of module : Magnetic switch monitoring
- function of module : Monitoring 2 PNP sensors
- function of module : Monitoring of electro-sensitive protection equipment (ESPE)
- function of module : Monitoring two-hand control station
- function of module : Proximity sensor monitoring
- function of module : RFID switch
- Global Keywords : Emergency Stop
- Global Keywords : Enabling switch
- Global Keywords : Guard switch
- Global Keywords : Harmony safety module
- Global Keywords : Machine safety
- Global Keywords : Magnetic switch
- Global Keywords : PNP sensor
- Global Keywords : Preventa
- Global Keywords : Protection of machines
- Global Keywords : Proximity safety switch
- Global Keywords : RFID switch
- Global Keywords : Safety control
- Global Keywords : Safety light curtain
- Global Keywords : Safety relay
- Global Keywords : Schneider electric
- Global Keywords : Two hand control station
- Global warming ; Total life cycle? : 70 kg CO2 eq.
- Height : 3.9 in (100 mm)
- input compatibility : 3-wire proximity sensors PNP
- input compatibility : Antivalent pair ISO 14119
- input compatibility : Mechanical contact ISO 14119
- input compatibility : Normally closed circuit ISO 13850
- input compatibility : Normally closed circuit ISO 14119
- input compatibility : OSSD pair IEC 61496-1-2
- input compatibility : Two-hand control EN 574/ISO 13851-III A
- input compatibility : Two-hand control EN 574/ISO 13851-III C
- input compatibility : XC limit switch ISO 14119
- input protection type : Internal, electronic
- Input/Output Type : Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
- IP Degree of Protection : IP20 terminals)IEC 60529
- IP Degree of Protection : IP40 housing)IEC 60529
- IP Degree of Protection : IP54 mounting area)IEC 60529
- Local Signalling : LED (green) for power ON
- Local Signalling : LED (red) for error
- Local Signalling : LED (yellow) for safety input S12
- Local Signalling : LED (yellow) for safety input S13
- Local Signalling : LED (yellow) for safety input S22
- Local Signalling : LED (yellow) for safety input S23
- Local Signalling : LED (yellow) for safety output status
- Local Signalling : LED (yellow) for start input
- Manufacturer : Square D
- maximum line resistance : 500 Ohm
- maximum response time on input open : 20 ms
- minimum output current : 10 mA relay output
- minimum output voltage : 12 V relay output
- Mounting Support : 35 mm symmetrical DIN rail
- Net Weight : 0.441 lb(US) (0.200 kg)
- Number Of Inputs : 2 safety input 24 V DC 5 mA
- Number Of Outputs : 3 on/off configurable pulsed output
- Number of Units in Package 2 : 16
- Number of Units in Package 3 : 128
- Package 2 GTIN : 43606489601810
- Package 2 Height : 11.81 in (30.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 11.316 lb(US) (5.133 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Package 3 Height : 29.53 in (75.000 cm)
- Package 3 Length : 31.50 in (80.000 cm)
- Package 3 Weight : 104.720 lb(US) (47.500 kg)
- Package 3 width : 23.62 in (60.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : No
- Power Consumption In Va : 5.0 VA 24 V AC 50/60 Hz
- Power Consumption in W : 2 W 24 V DC
- Product Certifications : CULus
- Product Certifications : TÜV
- Product Or Component Type : Safety module
- PVC free : Yes
- Relative Humidity : 5…95 % non-condensing
- safety level : Can reach PL e/category 4 ISO 13849-1
- safety level : Can reach SIL 3 IEC 61508
- safety level : Can reach SILCL 3 IEC 62061
- safety module application : For electrical monitoring of two-hand control stations
- safety module application : For emergency stop, guard and light curtain monitoring
- safety module application : For enabling switch monitoring
- safety module application : Monitoring antivalent contacts
- safety module name : XPSUS
- safety reliability data : Dcavg >= 99 % ISO 13849-1
- safety reliability data : HFT = 1 IEC 61508-1
- safety reliability data : HFT = 1 IEC 62061
- safety reliability data : MTTFd > 30 years ISO 13849-1
- safety reliability data : PFHd = 1.13E-09 IEC 61508-1
- safety reliability data : PFHd = 1.13E-09 IEC 62061
- safety reliability data : PFHd = 1.13E-09 ISO 13849-1
- safety reliability data : SFF > 99% IEC 61508-1
- safety reliability data : SFF > 99% IEC 62061
- safety reliability data : Type = B IEC 61508-1
- SCIP Number : 152cf799-1df7-4892-81b4-4c890187f1d1
- Standards : IEC 60947-5-1
- Standards : IEC 61508-1 functional safety standard
- Standards : IEC 61508-2 functional safety standard
- Standards : IEC 61508-3 functional safety standard
- Standards : IEC 61508-4 functional safety standard
- Standards : IEC 61508-5 functional safety standard
- Standards : IEC 61508-6 functional safety standard
- Standards : IEC 61508-7 functional safety standard
- Standards : IEC 62061 functional safety standard
- Standards : ISO 13849-1 functional safety standard
- synchronisation time between inputs : 0.5 s
- synchronisation time between inputs : 2 s
- synchronisation time between inputs : 4 s
- Take-back : No
- Temperature Shipping and Storage Range : -13…185 °F (-25…85 °C)
- type of start : Automatic/manual/monitored
- Unit Type of Package 2 : S03
- Unit Type of Package 3 : P06
- UNSPSC Classification v19 : 32151705
- UNSPSC Classification v23 : 32151705
- Volume of Package 2 : 36000.000 cm3
- Volume of Package 3 : 360000.000 cm3
- Width : 0.9 in (22.5 mm)