zoom

Product pictures shown represent the general type of component listed.The product you select might not exactly match the photo.

LC1D09BNE

$61.02
(No reviews yet) Write a Review
SKU:
LC1D09BNE
Adding to cart… The item has been added
TeSys D contactor 3P 9A AC-3 up to 440V coil 24-60V AC/DC
[Icw] rated short-time withstand current :
100 A - 1 s for signalling circuit~~
[Icw] rated short-time withstand current :
105 A 104 °F (40 °C) - 10 s for power circuit
[Icw] rated short-time withstand current :
120 A - 500 ms for signalling circuit
[Icw] rated short-time withstand current :
140 A - 100 ms for signalling circuit
[Icw] rated short-time withstand current :
210 A 104 °F (40 °C) - 1 s for power circuit
[Icw] rated short-time withstand current :
30 A 104 °F (40 °C) - 10 min for power circuit
[Icw] rated short-time withstand current :
61 A 104 °F (40 °C) - 1 min for power circuit
[Ie] rated operational current :
25 A (at
[Ie] rated operational current :
9 A (at
[Ith] conventional free air thermal current :
10 A (at 140 °F (60 °C)) for signalling circuit
[Ith] conventional free air thermal current :
25 A (at 140 °F (60 °C)) for power circuit
[Uc] control circuit voltage :
24...60 V AC 50/60 Hz
[Uc] control circuit voltage :
24...60 V DC
[Ue] rated operational voltage :
Power circuit
[Ui] rated insulation voltage :
Power circuit 690 V IEC 60947-4-1
[Ui] rated insulation voltage :
Signalling circuit 690 V IEC 60947-1
[Uimp] rated impulse withstand voltage :
6 kV IEC 60947
Associated Fuse Rating :
20 A gG at
Associated Fuse Rating :
25 A gG at
auxiliary contact composition :
1 NO + 1 NC
auxiliary contacts type :
Mirror contact 1 NC IEC 60947-4-1
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
8
climatic withstand :
IACS E10 exposure to damp heat
contactor application :
Motor control
contactor application :
Resistive load
control circuit type :
AC/DC 50/60 Hz AC/DC electronic
Depth :
3.4 in (86 mm)
Device Short Name :
LC1D
Electrical Durability :
0.6 Mcycles 25 A AC-1
Electrical Durability :
2.4 Mcycles 8 A AC-3
Electrical Durability :
2.4 Mcycles 8 A AC-3e
Final Result for Flywheel performance tracking :
Non Flywheel
Flame Retardance :
V1 conforming to UL 94
Global Keywords :
3-pole contactor
Global Keywords :
AC-3
Global Keywords :
AC-3e
Global Keywords :
Built-in auxiliary contact
Global Keywords :
Electronic AC/DC coil
Global Keywords :
LC1D
Global Keywords :
Low consumption
Global Keywords :
Magnetic contactor
Global Keywords :
Motor control
Global Keywords :
Motor switching
Global Keywords :
Power contactor
Global Keywords :
Screw clamp terminals
Global Keywords :
TeSys D
Global Keywords :
TeSys D Green
Global Keywords :
Wide control voltage
Global warming ; Total life cycle? :
8 kg CO2 eq.
Halogen content performance :
Halogen free plastic parts and cables product
Heat Dissipation :
0.6 W at 50/60 Hz
Height :
3.03 in (77 mm)
Hold-In Power Consumption In Va :
0.9 VA 50/60 Hz (at 68 °F (20 °C))
Hold-In Power Consumption In W :
0.6 W 68 °F (20 °C)
insulation resistance :
> 10 MOhm for signalling circuit
IP Degree of Protection :
IP20 front face IEC 60529
Manufacturer :
Square D
Maximum Horse Power Rating :
0.33 hp at 115 V AC 60 Hz for 1 phase motors
Maximum Horse Power Rating :
1 hp at 230/240 V AC 60 Hz for 1 phase motors
Maximum Horse Power Rating :
2 hp at 200/208 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
2 hp at 230/240 V AC 60 Hz for 3 phase motors
Maximum Horse Power Rating :
5 hp at 460/480 V AC 60 Hz for 3 phase motors
maximum operating rate :
3600 cyc/h at 60 °C
Mechanical Durability :
15 Mcycles
Mechanical Robustness :
Shocks contactor open 10 Gn for 11 ms)
minimum switching current :
5 mA for signalling circuit
minimum switching voltage :
17 V for signalling circuit
Mounting Support :
Plate
Mounting Support :
Rail
Number of Units in Package 2 :
15
Number of Units in Package 3 :
240
Operating Altitude :
0...9842.52 ft (0...3000 m)
Operating Time :
20...90 ms opening
Operating Time :
45...55 ms closing
Overvoltage Category :
III
Package 2 GTIN :
43606480987630
Package 2 Height :
5.91 in (15.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
13.834 lb(US) (6.275 kg)
Package 2 width :
11.81 in (30.000 cm)
Package 3 Height :
29.53 in (75.000 cm)
Package 3 Length :
31.50 in (80.000 cm)
Package 3 Weight :
221.344 lb(US) (100.400 kg)
Package 3 width :
23.62 in (60.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
Yes
Permissible Ambient Air Temperature Around The Dev :
140…158 °F (60…70 °C) with derating
Permissible Ambient Air Temperature Around The Dev :
-40…140 °F (-40…60 °C)
pole contact composition :
3 NO
Pollution Degree :
3
power dissipation per pole :
0.2 W AC-3
power dissipation per pole :
0.2 W AC-3e
power dissipation per pole :
1.56 W AC-1
Product Certifications :
CCC
Product Certifications :
CSA
Product Certifications :
DNV-GL
Product Certifications :
EAC
Product Certifications :
KC
Product Certifications :
LROS (Lloyds register of shipping)
Product Certifications :
UKCA
Product Certifications :
UL
Product Or Component Type :
Contactor
protective cover :
With
signalling circuit frequency :
25...400 Hz
Standards :
EN/IEC 60947-4-1
Standards :
EN/IEC 60947-5-1
Standards :
IEC 60335-1
Standards :
UL 60947-4-1
Sustainable packaging :
Yes
Take-back :
No
Type Of Network :
3P
Unit Type of Package 2 :
S02
Unit Type of Package 3 :
P06
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
utilisation category :
AC-1
utilisation category :
AC-3
utilisation category :
AC-3e
Volume of Package 2 :
18000.000 cm3
Volume of Package 3 :
360000.000 cm3
Warranty :
18 months
Width :
1.8 in (45 mm)

No Reviews Yet