Harmony, NFC modular timing relay, 8 A, 2 CO, 0.1 s…999 h, multifunction, 24...240 V AC/DC
- [Uc] control circuit voltage : 24...240 V~~
- [Uimp] rated impulse withstand voltage : 5 kV 1.2/50 µs IEC 60664-1
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 64
- Connections - Terminals : Screw connectors
- Connections - Terminals : Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
- Connections - Terminals : Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
- Connections - Terminals : Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- Connections - Terminals : Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
- Contacts Type And Composition : 1 C/O timed and instantaneous contact, cadmium free
- Contacts Type And Composition : 2 C/O
- Contacts Type And Composition : 2 C/O timed contact, cadmium free
- creepage distance : 4 kV/3 IEC 60664-1
- Device Short Name : RENF22
- dielectric strength : basic insulation
- dielectric strength : 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply with basic insulation
- Directives : 2014/30/EU - electromagnetic compatibility
- Directives : 2014/35/EU - low voltage directive
- Directives : 2014/53/EU - radio equipment directive
- Discrete Output Type : Relay
- Electrical Durability : 100000 cycles for resistive load, 8 A at 250 V, AC
- Electromagnetic Compatibility : Conducted emission class A conforming to EN 55022
- Electromagnetic Compatibility : Electromagnetic field immunity test - test level: 1 V/m level 1 (2...2.7 GHz) conforming to IEC 61000-4-3
- Electromagnetic Compatibility : Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
- Electromagnetic Compatibility : Electromagnetic field immunity test - test level: 3 V/m level 2 (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
- Electromagnetic Compatibility : Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
- Electromagnetic Compatibility : Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
- Electromagnetic Compatibility : Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
- Electromagnetic Compatibility : Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
- Electromagnetic Compatibility : Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
- Electromagnetic Compatibility : Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
- Electromagnetic Compatibility : Radiated emission class B conforming to EN 55022
- Electromagnetic Compatibility : Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
- Electromagnetic Compatibility : Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
- Final Result for Flywheel performance tracking : Non Flywheel
- Function Available : A- Power on-delay relay-2 C/O
- Function Available : Ac- On-delay and off-delay relay w/ control signal-2 C/O
- Function Available : Ad- Pulse delayed relay w/ control signal-2 C/O
- Function Available : Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O~~