TeSys D control relay, 3 NO + 2 NC
- [Icw] rated short-time withstand current : 100 A - 1 s~~
- [Icw] rated short-time withstand current : 120 A - 500 ms
- [Icw] rated short-time withstand current : 140 A - 100 ms
- [Ith] conventional free air thermal current : 10 A (at 140 °F (60 °C))
- [Uc] control circuit voltage : 240 V AC 50/60 Hz
- [Ui] rated insulation voltage : 600 V CSA
- [Ui] rated insulation voltage : 600 V UL
- [Ui] rated insulation voltage : 690 V IEC 60947-5-1
- [Uimp] rated impulse withstand voltage : 6 kV IEC 60947
- Ambient Air Temperature For Operation : 140-158 °F (60-70 °C) with derating
- Ambient Air Temperature For Operation : -40-140 °F (-40-60 °C)
- Associated Fuse Rating : 10 A gG conforming to IEC 60947-5-1
- Brand : Schneider Electric
- By Schneider : Yes
- Carbon footprint (kg CO2 eq, Total Life cycle) : 17
- Connections - Terminals : screw clamp terminals 1 0.002-0.006 in² (1-4 mm²)flexible with cable end
- Connections - Terminals : screw clamp terminals 1 0.002-0.006 in² (1-4 mm²)flexible without cable end
- Connections - Terminals : screw clamp terminals 1 0.002-0.006 in² (1-4 mm²)solid without cable end
- Connections - Terminals : screw clamp terminals 2 0.002-0.004 in² (1-2.5 mm²)flexible with cable end
- Connections - Terminals : screw clamp terminals 2 0.002-0.006 in² (1-4 mm²)flexible without cable end
- Connections - Terminals : screw clamp terminals 2 0.002-0.006 in² (1-4 mm²)solid without cable end
- contactor application : Control circuit
- control circuit type : AC 50/60 Hz
- control circuit voltage limits : 0.3...0.6 Uc (-40-158 °F (-40-70 °C)):drop-out AC 50/60 Hz
- control circuit voltage limits : 0.8...1.1 Uc (-40-140 °F (-40-60 °C)):operational AC 50 Hz
- control circuit voltage limits : 0.85...1.1 Uc (-40-140 °F (-40-60 °C)):operational AC 60 Hz
- control circuit voltage limits : 1...1.1 Uc (140-158 °F (60-70 °C)):operational AC 50/60 Hz
- Depth : 3.3 in (84 mm)
- Device Short Name : CAD
- Final Result for Flywheel performance tracking : Non Flywheel
- Global Keywords : 3NO+2NC
- Global Keywords : AC coil
- Global Keywords : AC control
- Global Keywords : Auxiliary contactor
- Global Keywords : CAD32
- Global Keywords : Control relay
- Global Keywords : Industrial relay
- Global Keywords : Screw clamp terminals
- Global Keywords : TeSys D
- Global warming ; Total life cycle? : 17 kg CO2 eq.
- Height : 3.03 in (77 mm)
- Hold-In Power Consumption In Va : 8 VA 50 Hz (at 68 °F (20 °C))
- inrush power in VA : 70 VA 50 Hz (at 68 °F (20 °C))
- insulation resistance : > 10 MOhm
- IP Degree of Protection : IP2x front face VDE 0106
- Irms rated making capacity : 140 A AC IEC 60947-5-1
- Irms rated making capacity : 250 A DC IEC 60947-5-1
- Manufacturer : Schneider Electric
- maximum operating rate : 180 cyc/mn
- Mechanical Durability : 30 Mcycles
- Mechanical Robustness : Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27
- Mechanical Robustness : Shocks control relay open10 Gn for 11 ms IEC 60068-2-27
- Mechanical Robustness : Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
- Mechanical Robustness : Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6
- minimum switching current : 5 mA
- minimum switching voltage : 17 V
- Mounting Support : Plate
- Mounting Support : Rail
- Net Weight : 1.28 lb(US) (0.58 kg)
- non-overlap time : 1.5 ms on de-energisation between NC and NO contact
- non-overlap time : 1.5 ms on energisation between NC and NO contact
- Number of Units in Package 2 : 20
- Operating Altitude : 0...9842.52 ft (0...3000 m)
- Operating Time : 12...22 ms coil energisation and NO closing
- Operating Time : 4...12 ms coil de-energisation and NO opening
- Operating Time : 4...19 ms coil energisation and NC opening
- Operating Time : 6...17 ms coil de-energisation and NC closing
- Package 2 GTIN : 13389110402381
- Package 2 Height : 5.91 in (15.000 cm)
- Package 2 Length : 15.75 in (40.000 cm)
- Package 2 Weight : 16.442 lb(US) (7.458 kg)
- Package 2 width : 11.81 in (30.000 cm)
- Packaging made with recycled cardboard : Yes
- Packaging without single use plastic : No
- pole contact composition : 3 NO + 2 NC
- Product Certifications : CB
- Product Certifications : CCC
- Product Certifications : CE
- Product Certifications : CSA
- Product Certifications : EAC
- Product Certifications : UKCA
- Product Certifications : UL
- Product Name : TeSys CAD
- Product Or Component Type : Control relay
- Protective Treatment : TH IEC 60068
- Range : TeSys
- Range : TeSys Deca
- SCIP Number : B67ac941-f42f-4afd-894a-0b6f9cefde62
- Standards : CSA C22.2 No 60947-5-1
- Standards : EN/IEC 60947-5-1
- Standards : GB/T 14048.5
- Standards : JIS C8201-5-1
- Standards : UL 60947-5-1
- Take-back : No
- Temperature Shipping and Storage Range : -76-176 °F (-60-80 °C)
- Tightening Torque : 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
- Tightening Torque : 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
- Tightening Torque : 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
- Unit Type of Package 2 : S02
- UNSPSC Classification v19 : 39122331
- UNSPSC Classification v23 : 39122331
- utilisation category : AC-14
- utilisation category : AC-15
- utilisation category : DC-13
- Volume of Package 2 : 18000.000 cm3
- Warranty : 18 months
- Width : 1.8 in (45 mm)