TeSys K Contactor |Number of Poles: 4-Poles|Pole Contact Composition: 4 NO|Rated Operational Current: 20A|Control Circuit Voltage: 220-230V AC 50/60 Hz|Non-Reversing
[Icw] rated short-time withstand current :
20 A 122 °F (50 °C) - >= 15 min for power circuit~~
[Icw] rated short-time withstand current :
40 A 122 °F (50 °C) - 3 min for power circuit
[Icw] rated short-time withstand current :
45 A 122 °F (50 °C) - 1 min for power circuit
[Icw] rated short-time withstand current :
60 A 122 °F (50 °C) - 30 s for power circuit
[Icw] rated short-time withstand current :
80 A 122 °F (50 °C) - 10 s for power circuit
[Icw] rated short-time withstand current :
85 A 122 °F (50 °C) - 5 s for power circuit
[Icw] rated short-time withstand current :
90 A 122 °F (50 °C) - 1 s for power circuit
[Ie] rated operational current :
20 A (at
[Ith] conventional free air thermal current :
10 A (at 122 °F (50 °C)) for signalling circuit
[Ith] conventional free air thermal current :
20 A (at 140 °F (60 °C)) for power circuit
[Uc] control circuit voltage :
220...230 V AC 50/60 Hz
[Ue] rated operational voltage :
Power circuit
[Ue] rated operational voltage :
Signalling circuit
[Ui] rated insulation voltage :
Power circuit 600 V CSA C22.2 No 14
[Ui] rated insulation voltage :
Power circuit 600 V UL 508
[Ui] rated insulation voltage :
Power circuit 690 V IEC 60947-4-1
[Uimp] rated impulse withstand voltage :
8 kV
Application :
Control
Associated Fuse Rating :
25 A aM for power circuit
Associated Fuse Rating :
25 A gG at
By Schneider :
Yes
Carbon footprint (kg CO2 eq, Total Life cycle) :
153
contactor application :
Resistive load
control circuit type :
AC 50/60 Hz silent
control circuit voltage limits :
Drop-out: >= 0.10 Uc (at
control circuit voltage limits :
Operational: 0.85...1.1 Uc (at
Depth :
2.2 in (57 mm)
Device Short Name :
LC7K
Electrical Durability :
0.16 Mcycles 20 A AC-1
Final Result for Flywheel performance tracking :
Non Flywheel
Flame Retardance :
V1 conforming to UL 94
Global Keywords :
Contactor
Global Keywords :
LC7K09004M7
Global Keywords :
TeSys K
Global warming ; Total life cycle? :
153 kg CO2 eq.
Heat Dissipation :
3 W
Height :
2.3 in (58 mm)
Hold-In Power Consumption In Va :
3 VA (at 68 °F (20 °C))
inrush power in VA :
3 VA (at 68 °F (20 °C))
IP Degree of Protection :
IP2x VDE 0106
Manufacturer :
Schneider Electric
maximum operating rate :
3600 cyc/h
Mechanical Durability :
10 Mcycles
Mounting Support :
Plate
Mounting Support :
Rail
Number of Units in Package 2 :
40
Overvoltage Category :
III
Package 2 GTIN :
43389110492697
Package 2 Height :
5.91 in (15.000 cm)
Package 2 Length :
15.75 in (40.000 cm)
Package 2 Weight :
20.316 lb(US) (9.215 kg)
Package 2 width :
11.81 in (30.000 cm)
Packaging made with recycled cardboard :
Yes
Packaging without single use plastic :
Yes
pole contact composition :
4 NO
Product Certifications :
CB Scheme
Product Certifications :
CCC
Product Certifications :
CE
Product Certifications :
CSA
Product Certifications :
EAC
Product Certifications :
UKCA
Product Certifications :
UL
Product Or Component Type :
Contactor
Protective Treatment :
TC DIN 50016
Protective Treatment :
TC IEC 60068
Range :
TeSys
rated breaking capacity :
110 A at 415 V conforming to IEC 60947
rated breaking capacity :
110 A at 440 V conforming to IEC 60947
rated breaking capacity :
80 A at 500 V conforming to IEC 60947
Standards :
EN/IEC 60947-4-1
Standards :
GB/T 14048.4
Standards :
JIS C8201-4-1
Standards :
UL 60947-4-1
Sustainable packaging :
Yes
Take-back :
No
Temperature Shipping and Storage Range :
-58…176 °F (-50…80 °C)
Type Of Network :
4P
Unit Type of Package 2 :
S02
UNSPSC Classification v19 :
39121529
UNSPSC Classification v23 :
39121529
utilisation category :
AC-1
Volume of Package 2 :
18000.000 cm3
Warranty :
18 months
Width :
1.8 in (45 mm)